Neware 8CH Battery Capacity Discharge Tester TWS Charge Chamber Capacity Cycler
Neware Battery Charge and Discharge Test System , ranging from uA single cell applications up to 1MW packs , is a high precision system designed specifically for testing lithium ion battery cells , modules , packs and capacitors . It is suitable for product development , quality control , and helpful to characteristic research , cycle life testing , product screening , and quality assessment .
BTS4000 is very possibly the correct choice for you to get to know Neware and her battery test products better .
Till year 2017 , 90percent new customers of Neware would choose BTS4000 as a starting point , its really the time - proven and reliable choice .
Voltage and Current - the Very Essential
The accuracies of Voltage and / or current may fundamentally affect the results come from a test . Thats why accuracies of voltage and current are so important to a battery tester .
Neware battery testers provide good accuracies both for voltage and current . This ensures you get the most reliable data from your tests .
A measurement system can be accurate but not precise , precise but not accurate , neither , or both . Neware battery testers provide good prrecision meanwhile . To get an overall performance of a measurement system , Measurement system analysis MSA is usually introduced for the study .
Recycle Battery Function
If you have recovery battery pack , like Toyota Prius battery pack - generally , each piece has 6 single NiMH cell , then several pieces batteries assembed in one pack , and you need to check each single cell for capacity , cyclie life , resistance , etc . Then assemble the battery cell after sorting by capacity , resistance . You will get the new battery pack . And last you will test the battery pack to check the real capacity and other function parameter .
20ms Response Time
This fast response time will meet rapidly changing power requirements
Flexible Integration of Hardware and Data Management
BTS 4000 functions also as the core part of auto formation and grading system . With its structural data system , testing data can be analysed , summarized , managed and utilized by our extended program or customers own data and logic server .
Data Recording | Record Condition | Min Time - 100mS |
Min Voltage - 10mV | ||
Min Current - Range 1 , 2mA Range 2 , 12mA Range 3 , 24mA | ||
Record Frequency | 10Hz | |
Charge | Charge Mode | CCCharge , CVCharge , CCCVCharge , CPCharge |
End Conditon | Voltage , Current , Relative Time , Capacity , -deltaV | |
Discharge | Discharge Mode | CCD , CPD , CRD |
End Condition | Voltage , Current , Relative Time , Capacity | |
Pulse | charge | CCC , CPC |
Discharge | CCD , CPD | |
Min Pulse Width | 500ms | |
Automated Switch | Automated swith from charge to discharge for each pulse | |
Cycle | Loop Measure Range | 65535 times |
Max Steps Per Loop | 254 | |
Nested Loop | Nested loop Function , Max Support 3 Layers | |
Protection | Software Protection | Power - down Data Protection |
Off - line Testing Function | ||
Setting Protection Condition,Setting Parameter - Low Voltage limit , Upper Voltage limit , Low Current limit , Upper Current limit , Delay Time | ||
A Means of Communication of Upper Machine | TCP / IP Protocol | |
Data Output | EXCEL , TXT , Graph | |
Per Unit Main Channels No. | 8 | |
Dimensions | 3U , 480 – 330 - 180mm |