Neware Lithium Ion Battery Tester IEC Standard DCIR Test Supported
1 . CT - 9004 , as our latest battery testing system , brings you up - to- date , sophisticated hardware technology and brand - new software experience . Its characterized with a maximum data acquisition frequency of 1000Hz , 4 automated - switch output ranges , 0.02percent accuracy and a minimum pulse width of 400μs .
2 . BTS9000 is based on Neware sixth - generation testing system . It's designed for battery material research , high - precision tests, pulse charge/discharge tests , DCIR test , and cycle life test .
3 . As the most cutting - edge equipment for battery material research , BTS9000 comes with extremely high accuracy 0.02 percent of FS , amazing hardware response speed - less than 100μs , wide range of applications , high - speed testing data acquisition and many other industry - proven characteristics , its your ultimate choice for battery material research .
4 . We designed and shipped our sophisticated series which is characterized with a max . data acquisition frequency of 1000Hz , a minimum pulse width reaching 400us , an accuracy of 0.02percent of FS and auto multi - current ranges enabled .
5 . Uninterrupted operation hours of 43000 hours , and equipment still outputs and measures accurately .
Project index | Parameter index | |
Voltage | Per Channel Voltage Range | 0 V~5V |
Min discharge voltage | 0.7 V - 0.5m cable , 5A discharge | |
Accuracy | 0.02percent of FS | |
Stability | 0.005percent of FS | |
Power | Per Channel Output Power | 25W |
Stability | 0.01 percent of FS | |
Time | Current Response Time | Less than 100μS |
Step Time Range | More than 10ms | |
Data Recording | Record Condition | Time delta T- more than 1ms |
Voltage delta U - more than 1mV | ||
Current delta I - more than 100nA | ||
Record Frequency | 1000Hz Continuous Charge / Discharge Mode / GSM Pulse Mode; | |
Charge | Charge Mode | Constant Current Charge , Constant Voltage Charge , Constant Current and Constant Voltage Charge , Constant Power Charge , Constant Resistance Charge |
End Conditon | Voltage , Current , Relative Time , Capacity , Energy , Power | |
Discharge | Discharge Mode | CCD / CPD / CRD / Pulse Discharge |
End Condition | Voltage , Current , Relative Time , Capacity | |
Cycle | Loop Measure Range | 65535 |
Max Steps Per Loop | 255 | |
Nested Loop | Nested loop Function , Max Support 3 Layers | |
Protection | Software Protection | Power - down Data Protection |
Off - line Testing Function | ||
Setting Protection Condition , Setting Parameter - Low Voltage limit , Upper Voltage limit - Low Current limit - Upper Current limit - Delay Time | ||
Database | MySQL Database | |
A Means of Communication of Upper Machine | TCP / IP Protocol , 100M Ethernet | |
Data Output | EXCEL2003 , 2010 , TXT |