Neware Cutting Edge Lithium Ion Battery Analyzer 1000Hz Data Record
CT - 9004 Cutting - edge Technology for Battery Material Research
1 . CT - 9004 , as our latest battery testing system , brings you up - to- date , sophisticated hardware technology and brand - new software experience .
2 . If you need highly accurate current output range to tell the subtle difference of the battery material , but don’t need many pulse tests , then CT - 9000 - 5V5A - 8CH is the better choice .
3 . Its characterized with a maximum data acquisition frequency of 1000Hz , 4 automated - switch output ranges , 0.02percent accuracy and a minimum pulse width of 400μs .
4 . CT - 9000 is mainly designed for Battery research insitutues , universities and laboratories of battery companies.
5 . Neware CT - 9000 is the best ever battery tester from Neware , it came into the market with extremely high accuracy , Amazingly quick hardware response time , high - speed data acquisition frequency and many other industry - proven characteristics , it can tell the subtle difference of all kinds of battery materials , it helps you to find the future battery material and solution .
GSM TEST / PULSE TEST / DCIR TEST
1 . BTS9000 is based on Neware sixth - generation testing system . It's designed for battery material research , high - precision tests, pulse charge/discharge tests , DCIR test , and cycle life test .
2 . Uninterrupted operation hours of 43000 hours , and equipment still outputs and measures accurately .
3 . As the most cutting - edge equipment for battery material research , BTS9000 comes with extremely high accuracy 0.02 percent of FS , amazing hardware response speed - less than 100μs , wide range of applications , high - speed testing data acquisition and many other industry - proven characteristics , its your ultimate choice for battery material research .
Current | Current range | range1 , 0.1uA -150uA |
range2 , 140uA - 5mA | ||
range3 , 4.5mA - 150mA | ||
range4 , 140mA - 5A | ||
Accuracy | 0.02 percent of FS | |
range1 , 30nA | ||
range2 , 1uA | ||
range3 , 30uA | ||
range4 , 1mA | ||
Stability | 0.005 percent of FS | |
Charge | Charge Mode | Constant Current Charge , Constant Voltage Charge , Constant Current and Constant Voltage Charge , Constant Power Charge , Constant Resistance Charge |
End Conditon | Voltage , Current , Relative Time , Capacity , Energy , Power | |
Discharge | Discharge Mode | CCD / CPD / CRD / Pulse Discharge |
End Condition | Voltage , Current , Relative Time , Capacity | |
DCIR | Support for the calculation of the point of the DCIR | |
Protection | Software Protection | Power - down Data Protection |
Off - line Testing Function | ||
Setting Protection Condition , Setting Parameter - Low Voltage limit , Upper Voltage limit - Low Current limit - Upper Current limit - Delay Time |