Neware 5V5A Lithium Ion Battery Charge Discharge Analysis Tester
1 . 43,000 Hours - 5 years
Uninterrupted operation hours of 43000 hours , and equipment still outputs and measures accurately .
2 . 1000HZ
We designed and shipped our sophisticated series which is characterized with a max . data acquisition frequency of 1000Hz , a minimum pulse width reaching 400us , an accuracy of 0.02percent of FS and auto multi - current ranges enabled .
3 . Cutting - edge Technology for Battery Material Research
CT - 9004 , as our latest battery testing system , brings you up - to- date , sophisticated hardware technology and brand - new software experience . Its characterized with a maximum data acquisition frequency of 1000Hz , 4 automated - switch output ranges , 0.02percent accuracy and a minimum pulse width of 400μs .
4 . GSM TEST / PULSE TEST / DCIR TEST
BTS9000 is based on Neware sixth - generation testing system . It's designed for battery material research , high - precision tests, pulse charge/discharge tests , DCIR test , and cycle life test .
As the most cutting - edge equipment for battery material research , BTS9000 comes with extremely high accuracy 0.02 percent of FS , amazing hardware response speed - less than 100μs , wide range of applications , high - speed testing data acquisition and many other industry - proven characteristics , its your ultimate choice for battery material research .
Neware CT - 9000 is the best ever battery tester from Neware , it came into the market with extremely high accuracy , Amazingly quick hardware response time , high - speed data acquisition frequency and many other industry - proven characteristics , it can tell the subtle difference of all kinds of battery materials , it helps you to find the future battery material and solution . CT - 9000 is mainly designed for Battery research insitutues , universities and laboratories of battery companies.
The core technologies are improvement on a new height , such as 8channel design , 0.02percent of FS accuracy, 1000Hz data acquisition frequency , multi - range , supporting GSM and CDMA . If you need highly accurate current output range to tell the subtle difference of the battery material , but don’t need many pulse tests , then CT - 9000 - 5V5A - 8CH is the better choice .
Project index | Parameter index | |
Voltage | Per Channel Voltage Range | 0 V~5V |
Min discharge voltage | 0.7 V - 0.5m cable , 5A discharge | |
Accuracy | 0.02percent of FS | |
Stability | 0.005percent of FS | |
Power | Per Channel Output Power | 25W |
Stability | 0.01 percent of FS | |
Time | Current Response Time | Less than 100μS |
Step Time Range | More than 10ms | |
Data Recording | Record Condition | Time delta T- more than 1ms |
Voltage delta U - more than 1mV | ||
Current delta I - more than 100nA | ||
Record Frequency | 1000Hz Continuous Charge / Discharge Mode / GSM Pulse Mode; | |
Discharge | Discharge Mode | CCD / CPD / CRD / Pulse Discharge |
End Condition | Voltage , Current , Relative Time , Capacity | |
Pulse mode | Charge | CC , CP mode |
Discharge | CC , CP mode | |
Min pulse width | 400μs | |
Pulse number | Single pulse working step supports 16 different pulse segments | |
End Condition | Voltage , Relative Time | |
DCIR | Support for the calculation of the point of the DCIR | |
Database | MySQL Database | |
A Means of Communication of Upper Machine | TCP / IP Protocol , 100M Ethernet | |
Per Unit Main Channels No. | 4 | |
Dimensions | WDH , 585 - 575 - 130mm |