Neware Lithium Ion Battery Tester for Battery Material Research
The core technologies are improvement on a new height , such as 8channel design , 0.02percent of FS accuracy, 1000Hz data acquisition frequency , multi - range , supporting GSM and CDMA . If you need highly accurate current output range to tell the subtle difference of the battery material , but don’t need many pulse tests , then CT - 9000 - 5V5A - 8CH is the better choice .
Accuracy 0.02percent of FS , 4 auto - switch output ranges , 400us pulse width, 1000Hz data record frequency , characterized above and even more advanced features , Neware BTS9000 is born to be the most advanced battery testing system , it is the best choice for you to find the future battery material .
GSM TEST / PULSE TEST / DCIR TEST
1 . BTS9000 is based on Neware sixth - generation testing system .
2 . It's designed for battery material research , high - precision tests, pulse charge/discharge tests , DCIR test , and cycle life test .
3 . As the most cutting - edge equipment for battery material research , BTS9000 comes with extremely high accuracy 0.02 percent of FS , amazing hardware response speed - less than 100μs , wide range of applications , high - speed testing data acquisition and many other industry - proven characteristics , its your ultimate choice for battery material research .
1000HZ
1 . We designed and shipped our sophisticated series which is characterized with a max .
3 . Data acquisition frequency of 1000Hz , a minimum pulse width reaching 400us , an accuracy of 0.02percent of FS and auto multi - current ranges enabled .
43,000 Hours - 5 years
Uninterrupted operation hours of 43000 hours , and equipment still outputs and measures accurately .
Current | Current range | range1 , 0.1uA -150uA |
range2 , 140uA - 5mA | ||
range3 , 4.5mA - 150mA | ||
range4 , 140mA - 5A | ||
Accuracy | 0.02 percent of FS | |
range1 , 30nA | ||
range2 , 1uA | ||
range3 , 30uA | ||
range4 , 1mA | ||
Stability | 0.005 percent of FS | |
Power | Per Channel Output Power | 25W |
Stability | 0.01 percent of FS | |
Time | Current Response Time | Less than 100μS |
Step Time Range | More than 10ms | |
Data Recording | Record Condition | Time delta T- more than 1ms |
Voltage delta U - more than 1mV | ||
Current delta I - more than 100nA | ||
Record Frequency | 1000Hz Continuous Charge / Discharge Mode / GSM Pulse Mode; | |
Charge | Charge Mode | Constant Current Charge , Constant Voltage Charge , Constant Current and Constant Voltage Charge , Constant Power Charge , Constant Resistance Charge |
End Conditon | Voltage , Current , Relative Time , Capacity , Energy , Power | |
Discharge | Discharge Mode | CCD / CPD / CRD / Pulse Discharge |
End Condition | Voltage , Current , Relative Time , Capacity |