Lithium Ion Battery Testing Equipment Multipurpose Antiwear battery managment tester
1. Scope Of Application
The BMS tester is applied to 1-24 strings of lithium battery protection plate safety test , test whether the function index within the range of reasonable parameters , to provide a set of testing standards , is conducive to improve production efficiency , convenient quality control , compatible with market common protection plate type , positive port ( port ) , negative port ( port ) , positive charge negative release , etc
2. Facility Environment
No strong vibration environment , no corrosive gas and flammable and explosive gas existence
3. Equipment Description
3.1 Test parameters
Project Type | Test Specification | Resolution Ratio |
Test The Number Of Strings | 1-24 Strings | |
Reference Voltage | 0.5-5V | ±1mV |
Overcharge To Protect Voltage | 0.5-5V | ±1mV |
Overcharge Protection Is Lifted | 0.5-5V | ±1mV |
Overdischarge Protection Voltage | 0.5-5V | ±1mV |
Overrelease Protection Is Lifted | 0.5-5V | ±1mV |
Overdischarge Current Protection Value | 1-150A | ±0.1A |
Overcharge Flow Protection Value | 1-40A | ±0.1A |
Overflow Protection Delay | 0-10S | ±1ms |
Overcharge / Overcharge Protection Delay | 0-20S | ±1ms |
Balanced Turn On Voltage | 0.5-5V | ±5mV |
Balanced Turn On Current | 0-200mA | ±1mA |
Single Section Self - Consumption | 0-500uA | ±1uA |
Internal Circuit Resistance Test | 0-200mΩ | ±1mΩ |
Short - Circuit Protection ( More Than 6 Strings ) | 0-9999uS | ±1uS |
3.2 Test items
Name |
PBTS24-120 |
Number of test strings |
1-24 |
Basic functions |
1. Internal resistance test 2. Individual Overcharge and over discharge voltage 3. Individual Overcharge and Discharge Recovery Voltage 4.Overcharge/discharge protection delay 5.Charge/discharge protection current 6. Charge/discharge over current delay 7.Single secondary overcharge and over discharge delay
|
Special test items |
1. Single section self-consumption test(Refers to the true and accurate power consumption per section) 2.Equalizing current and equalizing voltage(It can accurately grasp the balance current and the balance open voltage 3. Test Order Support Adjustment
|
Test program startup |
Support barcode scanning self-start/manual start |
Test Data |
Data sheets can be generated and saved for easy product traceability |
Application |
Measurement of lithium battery protection plate of ternary material, lithium iron phosphate, lithium cobalt, lithium manganese and so on. |
protective function |
Hardware boards and most software boards (special software boards BMS need to communicate) |
Module |
1.High current module: current level is 120A, current accuracy ±0.1A 2. Voltage module: programmable output 0.5-5V, accuracy ±5mV 3.Short-circuit module: super capacitor instantly provides 400A short-circuit current, test out the short-circuit delay time |