Equipment Environment Requirements And Technical Parameters For Battery Capacity Tester
1. Equipment Environment Requirements And Technical Parameters
1) Power supply AC voltage 380V ± 10% , frequency 50Hz ± 10%
2) Ambient temperature -10 ~ 45℃
3) No strong vibration environment , no corrosive gas and flammable and explosive gas existence .
2. Test Item
Battery charging protection voltage , discharge protection voltage, capacity , etc.
It has 4 steps such as charge discharge shelve and cycling.
3. Equipment Parameter Description
Product model | BCDS70-10-20 | |
Voltage | measuring range | 7 ~ 70V |
precision | ± ( 0.2% of reading + 0.2% of range) | |
Current | Charging range | 50~ 10000mA |
Discharge range | 50 ~ 20000mA | |
precision | ±(0.2% of reading + 0.2% of range ) | |
Battery charging | Constant pressure cut - off current | Minimum 50 mA |
Volume | precision | ±1‰ |
Power | Discharge power | ≤ 1400W |
Time | Inspection time | Receive real - time < 2S |
Timed range | 0~999 Hours / Step | |
Data recording interval | ≥5S | |
Medium machine version | 1.1 Series |
4. FAQ
1) How long is the warranty ?
If the equipment parts are damaged , the equipment warranty period is 1 year for 1 year due to non - human factors , and we will provide the replacement parts at cost.
2) How to order ?
Please send us your purchase order by email or call us salesor we can make the proforma invoice under your request
We need to know the following information for your order before sending your PI.
3) How many days does it take to purchase the equipment for delivery?
We will arrange the delivery items as soon as you pay for the equipment , predict 10-15work day send to .