Professional BMS Tester for Power Battery Protection Plate Testing 16 Strings 120A Excessive Flow
1. Brief Introduction
It is mainly used to detect whether the functional indicators of the power battery protection plate are within the parameter range , so as to provide a set of testing standards for the staff . Suitable for protection plate manufacturers and power battery manufacturers of power battery protection plate testing
2. Equipment Parameter Description
Project Type | Test Specification | Resolution Ratio |
Test The Number Of Strings | 1-24 Strings | |
Reference Voltage | 0.5-5V | ±1mV |
Overcharge To Protect Voltage | 0.5-5V | ±1mV |
Overcharge Protection Is Lifted | 0.5-5V | ±1mV |
Overdischarge Protection Voltage | 0.5-5V | ±1mV |
Overrelease Protection Is Lifted | 0.5-5V | ±1mV |
Overdischarge Current Protection Value | 1-150A | ±0.1A |
Overcharge Flow Protection Value | 1-40A | ±0.1A |
Overflow Protection Delay | 0-10S | ±1ms |
Overcharge / Overcharge Protection Delay | 0-20S | ±1ms |
Balanced Turn On Voltage | 0.5-5V | ±5mV |
3. Product Mix
Case Size | 510*500*220mm(W*D*H ) |
weight | 23KG |
Number Of Channels | 1 |
Equipment Accessories | Test table pen line , online data line , user manual, upper computer software. |
4. FAQ
How To Order ?
Please send us your purchase order by email or call us salesor we can make the proforma invoice under your request.
Are you a trading company or factory?
We are a factory more than 10 years.