Product information:
This test conforms to the standard requirements of IEC540. It is used for cold bend test of the circular insulation wire core whose diameter is small and the sector-shaped insulation wire core which can not be used for dumbbell. The apparatus shall be held in a refrigerator before and during the test.
The diameter of the mandrel shall be between 4 and 5 times the diameter of the test piece (see below).
The mandrel shall be uniformly rotated at a rate of one revolution in about 5 s and the number of turns shall be as specified in the following table.
Technical parameters:
1. Diameter of samples: 2.5~12.5㎜
Overall diameter (d) of the test piece (mm) | of turns Number |
d≤2.5 | 10 |
2.5<d≤4.5 | 6 |
4.5<d≤6.5 | 4 |
6.5<d≤8.5 | 3 |
8.5<d | 2 |
2. Diameter of pipe: 3,4,5,6,7,8,9,10,12,14,16(mm)
3. Diameter of test bar: 9.6,12.5,16,20,25,31.5,40,50(mm)