Specifications
Brand Name :
raycus
Model Number :
raycus 4000
Certification :
ce
Description

4000w raycus fiber laser source4000w raycus fiber laser source

1.1 Specifications

The specifications are listed in the following table

Table 5 Specifications

Table 6 Product SpecificationsModel C4000S Test Conditions
Optical Specifications
Nominal Output Power (W) 4000-4200
Operation Modes CW/Modulated
Polarization State Random
Output Power Tunability(%) 10~100
Emission Wavelength(nm) 1080±5 Nominal Output Power

Output Power Instability(%)

±1

Nominal Output Power
Operation Time:≥5h
Ambient Temperature: 22±1℃
Modulation Frequency(Hz) 1~5,000

Minimum laser pulse

width>160us

Red Guide Laser Power(mW) 0.5~1
Optical Output Characteristics of QBH head
Beam Quality(mm×mrad) 1.5~2 Nominal Output Power
Fiber Core Diameter(μm) 50 Diameter customizable
Numerical Aperture 0.2
Delivery Cable Length(m) 20 Length customizable
Electrical Characteristics
Power Supply 380±10% V AC,50/60Hz
Max. Power Consumption(W) 12500
Control Mode RS-232/AD/Ethernet
Other Characteristics
Dimensions(W×H×D)(mm) 1 02×4 7×250(include. handles))
Weight(kg) <80
Operating Ambient Temperature (℃) 10~40

Humidity (%) 30~70
Storage Temperature (℃) -10~60
Cooling Method Water Cooling

4000w raycus fiber laser source

1. REM/OFF/ON: Key switch, the control system power switch of the laser. Insert the key; either turning the key clockwise to the 'ON' position or counterclockwise to 'REM' position will power on the laser control system. Then the laser will enter a control mode depending on your previous setup on the 'CTRL-INTERFACE'. You can refer to 4.9 Control Mode for more details.

2. POWER: The control system power, LIGHT, indicates that the control system is

switched on.

3. START: Laser main power button,GREEN,when this button is pressed down,the laser is ready to emit laser.

4. LASER: Laser emission indicator, RED, illuminates when laser emission is on.

5. ALARM: Alarm indicator, YELLOW, indicates an error condition.

6. EMERGENCY STOP: Press it down to stop the laser immediately. When the button is in the ‘down’ position, turn it clockwise to release, but the laser cannot start before it’s powered on with key switch for a second time.4000w raycus fiber laser source

1. AC INPUT: The socket for supply source input that can only be mated with the plug on the power cord we provided.

2. POWER: Air switch to control the switching of AC.

3. CTRL-INTERFACE: Control interface, this interface is a male 24-needles connector and it’s multi-functional. The end users can set the control mode and input analog control signal with the interface, as well as get the fault signal from it.

4. WATER: Pipe connectors, the inlet and outlet for cooling water to flow in and return. (See Table 6 for the laser model and corresponding water pipe size for cooling system requirements)

5. ETHERNET: Ethernet interface. It can provide remote control and storage alarm information for the laser.

6. CDA: Clean Dry Air input. Clean dry air is input here to prevent dew formation.

The application of CDA:

If the CDA is provided by the customer, it must be cooled and dried by the dryer, then filtered by 5μm-particle and 0.3μm-particle filter, and 0.1μm atomized lubricator. The temperature of CDA must be in the range of 5~40℃, and the highest dew point is 0℃(It is suggested the temperature of CDA is 5℃ below the temperature of cooling water). The pressure of CDA is below 0.1 MPa, the flow rate is 10 LPM, and the outer diameter of pipe mated with the connector is 6mm.

If the CDA filter module provided by Raycus is used, the CDA should be also cooled and dried by the dryer, and the pressure should be below 0.8MPa, the outer diameter of pipe mated with the connector is 6mm.

The CDA should be input 30 min before the start of the laser. If the ambient temperature is below 25℃ and the humidity is below 50%, the CDA is unnecessary.

1.1 Power Connection

Table 7 Power Connection Requirements

Model RFL-C4000S
Supply Source 380±10% V AC 50/60Hz

Power Cord

One End of Power Cord Four wires labeled L1,L2,L3and PE.
Sign Description

L1,L2,L3-> Phase Line

PE-> Protective Earth

1.2 Interface Definitions

4.4.1 CTRL-INTERFACE Definitions

The CTRL-INTERFACE is for laser control, the designation and definition is below:

Figure 8 CTRL-INTERFACE

Table 8 Definitions of 24 pin Ctrl Interface

PIN

No.

Name

Line Mark

Type

Level

Drive Current

Typical Response Time

Description

1 Interlock2A ITL-2A

Contact Closure Input

24VDC

<1A

<500ms

Passive contact, not connected to external voltage or grounding.

2 Interlock1A ITL-1A
3 Interlock1B ITL-1B
4 Interlock2B ITL-2B
5 RS232Tx TX

120ms

Transmit Data
6 RS232Rx RX Receive Data
7 RS232Com GND RS-232 Return

8

Remote Key Switch

RPA

Contact Closure Input

24VDC

<1A

<1s

Activates the internal control system power supply in REMOTE mode. Passive contact, not connected to

e xternal voltage or

grounding.

9

RPB

10

Remote Start Button

START-A

Instantaneous Contact Closure Input

24VDC

<1s

In REMOTE mode, start
the laser main power
supply.Passive contact,

11

START-B

not connected to
external voltage or
grounding.

12

Analog Input to Control Current

1-10V

Analog Input

1-10VDC

1 mA

100us

Analog Input 1-10 VDC= 10 – 100% Setpoint

13

Analog Output Power Monitor

AOUT

Analog Output

0-8VDC

11mA

100µs

Analog Output 0-8 VDC

(Refer to factory inspection report for details)

14

Isolated Analog Com

GND1

Return

Return for signals on pins 12, 13,19,22,23,24
15 Modulation+ MOD+ Digital Input 5-24VDC 6 mA 20µs 5 -24 VDC Input
16 Modulation- MOD— Return Return for signal on pin 15

17

Guided Laser Control

RED-LASE R

Digital Input

5-24Vdc

6 mA

120ms

Positive edge activates emission in REMOTE

mode

18

Emission Enable

LAS—C

Digital Input

5-24VDC

6 mA

1ms

Positive edge activates emission in REMOTE mode

19

System error

(ERROR)

S-ERR

Digital output

24VDC

100mA

120ms

High=System error

20

System Common

GND2

Return

Return for pin 17,18,21

21

Error RESET

RESET

Digital Input

5-24VDC

6 mA

120ms

Rising edge reset (the
resettable alarm)
22 READY READY Digital output 24VDC 100mA 120ms High=Laser is ready
22 Power started POWER Digital output 24VDC 100mA 120ms High= The main power s upply is started
23 Laser emission LASER Digital output 24VDC 100mA 100ms High=Laser is emission

4000w raycus fiber laser source

Send your message to this supplier
Send Now

4000w raycus fiber laser source

Ask Latest Price
Brand Name :
raycus
Model Number :
raycus 4000
Certification :
ce
Contact Supplier
4000w raycus fiber laser source
4000w raycus fiber laser source
4000w raycus fiber laser source

Wuhan Bochuangxing Laser Technology Co., Ltd.

Site Member
5 Years
hubei
Since 2016
Business Type :
Manufacturer, Exporter, Trading Company
Total Annual :
3000000-7000000
Employee Number :
100~120
Certification Level :
Site Member
Contact Supplier