Specifications
Brand Name :
JINHAIHU
Model Number :
DSC-500A1
Certification :
ISO 9001
Place of Origin :
CHINA
MOQ :
1 set
Payment Terms :
T/T, Western Union, MoneyGram
Supply Ability :
10 sets per month
Packaging Details :
Carton
Product name :
Differential Scanning Calorimeter (DSC)
Temperature Range :
Rt-500℃
Temperature Resolution :
0.01℃
Heating Rate :
0.1~80℃/Min
Dsc Range :
0~±500mw
Dsc Resolution :
0.01mw
Dsc Sensitivity :
0.01mw
Working Power :
Ac 220V 50Hz 300W Or Other
Gas Flow :
0-200ml/Min
Gas Pressure :
0.2Mpa
Description

DSC- thermal analysis instrument differential scanning calorimeter (DSC)

One-key operation, automatic operation, is othermal Oxidative induction time special equipment

Conforming the following standards: GB/T 19466.3- 2009/ISO 11357-3:1999

Features:

  • New sensor sample support, fully closed structure design, prevent items from falling into the furnace body.
  • Built-in 10.8-inch computer, no additional computer, integrated equipment; The display is rich in information, including setting temperature, sample temperature, oxygen flow rate, nitrogen flow rate, differential heat signal, various switching states, etc.
  • The right side of the instrument is equipped with standard four USB interfaces, which are convenient for users to connect external devices such as mouse, keyboard, printer and USB flash drive, and convenient for users to use.
  • Pre-installed software, reduce computer adaptability problems, reduce due to the replacement of the use of the computer, installation drive error caused by the connection problems.
  • Windows 10 system is equipped with 32GB capacity and 2GB system memory. Data can be stored inside the instrument without u-disk transfer. The touch screen and mouse button can be used for operation
  • The furnace structure is compact, and the rate of rising and cooling is adjustable.
  • The installation process is improved, and the mechanical fixation method is adopted to completely avoid the contamination of the internal colloidal of the furnace to the differential heat signal.
  • The furnace is heated by heating wire, compact structure and small size.
  • The double temperature probe ensures the high repeatability of the sample temperature measurement, and adopts the special temperature control technology to control the temperature of the furnace wall to set the temperature of the sample.
  • The gas flow meter automatically switches between two channels of gas, with fast switching speed and short stable time.
  • Standard sample is provided for easy adjustment of temperature coefficient.
  • Software support each resolution screen, automatically adjust the computer screen size curve display mode. Support laptop, desktop; Support Win2000, XP, VISTA, WIN7, WIN8, WIN10 and other operating systems.
  • Support user edit device operation mode according to actual needs to achieve full automation of measurement steps. The software provides dozens of instructions, and users can flexibly combine and save each instruction according to their own measurement steps. Complex operations are reduced to one-click operations.

Parameters:

Temperature Range Rt-500℃
Temperature Resolution 0.01℃
Heating Rate 0.1~80℃/Min
Constant Temperature Rt-500℃
Duration Of Constant Temperature The Duration Is Recommended To Be Less Than 24 Hours.
Temperature Control Mode Constant Temperature Rise, Constant Temperature
Dsc Range 0~±500mw
Dsc Resolution 0.01mw
Dsc Sensitivity 0.01mw
Working Power Ac 220V 50Hz 300W Or Other
Atmosphere Control Gas Two-Channel Gas Control By Automatic Controlled (e.g. Nitrogen And Oxygen)
Gas Flow 0-200ml/Min
Gas Pressure 0.2Mpa
Gas Flow Accuracy 0.2ml/Min
Crucible Aluminium Crucible Φ6.6*3mm (Diameter * High)
Calibration Standard With Standard Material (Indium, Tin, Zinc), Users Can Adjust The Temperature By Themselves
Data Interface Standard Usb Interface
Display Mode 8-Inch Touch Computer
Output Mode Computer And Printer
Structure Design Fully Closed Support Structure Design, Prevent Items Falling Into The Furnace Body, Pollution Of The Furnace Body, Reduce The Maintenance Rate

Configuration list:

  • A DSC machine with a 10.8-inch touch computer
  • A set of mouse and keyboard and four AAA batteries
  • 300 Aluminium crucibles
  • A power cords
  • A CD (contains software and operations video)
  • A Soft-key
  • Oxygen airway and nitrogen airway, each 5m
  • A operation manual
  • A Standard sample(contains Indium, tin, zinc)
  • A tweezer and a medicine spoon
  • 2 pairs of custom pressure reducing valve joint and quick joint
  • 4 fused glass fuses

Instrument furnace structure:

DSC Plastic Analyzer Thermal Analysis Instrument With 0.2Mpa Gas PressureDSC Plastic Analyzer Thermal Analysis Instrument With 0.2Mpa Gas Pressure

Software screenshots:

DSC Plastic Analyzer Thermal Analysis Instrument With 0.2Mpa Gas PressureDSC Plastic Analyzer Thermal Analysis Instrument With 0.2Mpa Gas Pressure

Send your message to this supplier
Send Now

DSC Plastic Analyzer Thermal Analysis Instrument With 0.2Mpa Gas Pressure

Ask Latest Price
Brand Name :
JINHAIHU
Model Number :
DSC-500A1
Certification :
ISO 9001
Place of Origin :
CHINA
MOQ :
1 set
Payment Terms :
T/T, Western Union, MoneyGram
Contact Supplier
DSC Plastic Analyzer Thermal Analysis Instrument With 0.2Mpa Gas Pressure

Beijing Jinshengxin Testing Machine Co., Ltd.

Verified Supplier
8 Years
beijing, beijing
Since 2013
Business Type :
Manufacturer, Seller
Employee Number :
50~100
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement