Product Discription
LSS oil and gas fired vertical steam generator
The vertical vapour generator LSS adopts a vertical tubular structure. There are two tubular beam rings and a welded shell tube between the upper and lower plates of the main body to form a three -cycle effluent gas. The effluent gas has a transfer process The burner is placed on the top of the body, and the flame can expand and burn completely.
Using boiler and condenser, thermal efficiency can reach 93%100%.Built -in steam separator and external steam -water separator provide high quality dry steam, save fuel, reduce system scaling and prolong service life.
1. In accordance with environmental requirements:
High quality and reliable fuel can cause the fuel to burn completely and significantly reduce harmful gas emissions.
2. Evaporation may be increased:
Steam production can be configured in many units (unlimited number) and controlled by the computer.
3. The facility is complete:
The space can be connected to water, electricity and steam pipes to save installation time and energy.
4. Reliable components:
Support burners, control boxes, water treatment, valves, pumps and other high -quality household equipment.
5. Exceptional control system:
The boiler has a perfect automatic control device and safety device for the application of an automatic water level control system; and alarm and interruption of the water level; automatic steam pressure control system and excess pressure alarm;
6. Good service:
Technical consultation, technical services, installation guidance, regular and informal visits to users, at all times to provide quality waste services, so that users can be quiet and buy
Technical Parameters
Main Technical Reference for Fuel (Gas) Steam Generator
Item Unit | LSS0.05 | LSS0.1 | LSS0.15 | LSS0J2 | ||
Rated evaporation | Kg/h | 50 | 100 | 150 | 200 | |
Rated Pressure PTEPREppoPressure | MPa | 0.4/0.7 | ||||
Rated steam temperature | c | 151/171 | ||||
Rated feed water temperature | °C | 20 | ||||
Evaporator efficiency | / | >92% | ||||
Applicable Fuel | / | Gas light oil | ||||
Theoretical fuel consumption | Gas | NM3/h | 4 | 8 | 12 | 16 |
Light Oil | Kg/h | 3.3 | 6.5 | 9.8 | 13 | |
Gas supply pressure | mbar | 60- 100 | ||||
water volume | L | <30 |
Note: The fuel consumption in the table is based on the low calorific value of biomass particles 17084 KJ/Kg (4085 Kcal/Kg).Calculations show that if the low calorific value of biomass fuel is higher than that, the corresponding fuel consumption will be more economical than the values in the table.
Configuration and Interface Size of Fuel (Gas) Steam Generator
Item Unit | LSS0.05 | LSSO.l | LSS0.15 | LSS0.2 | ||
Outward Size of Main Engine
(length * width * height) | / | mm | 620*620*830 | 690*690*968 | 750*750*1130 | 800*800*1286 |
Transport Dimension
| / | t | 206 | 252 | 303 | 350 |
Mainframe Transport Weight | DN | mm | G 1/2- | Gl' | Gl" | G 1* |
Main Steam Valve Pipe Diameter | DN | mm | Gl/2" | Gl/2- | Gl/2- | Gl/2° |
Feed Water Valve | DN | mm | G1 1/4” | G11/4- | G11/4- | G11/4- |
Safety Valve Diameter | DN | mm | Gf | GF | Gl" | Gl" |
Drain Valve Pipe Diameter | DN | mm | 133 | 133 | 159 | 159 |
Remarks: We will reserve rights to change the above mentioned data due to continuous policy transformation and product improvement.