Product Features
1. Easy to Install:
The kitchen is economical, portable, short-lived and on-site, integrated inside the factory and can be installed on time.
2. The real approach:
Thermal control, water distribution and wet floor heating should ensure safe operation with heat and cold.
3. Easy to maintain:
The control panel and installation package can be modified and checked. The cigarette box on the front of the pan is easy to open, easy to view and check for proper functioning.
4. Heat:
The dual air oven is designed to protect against smoke and heat.
5. Storage of the crocodile:
Fuel and oil rentals begin to regulate the air to prevent sudden flow. Easy to understand.
6. To:
The pork ash is stable, regulates the accumulation of blue and hot water, prevents obstacles, removes the blue pot and combines several boiler loads.
Technical Parameters
Main Technical Parameters of DZH Series Biomass Steam Boiler
Item | Unit | DZH1 | DZH2 | DZH3 | DZH4 | DZH6 | DZH8 | DZH10 |
Steam Capacity | t/h | 1 | 2 | 3 | 4 | 6 | 8 | 10 |
Working Pressure | MPa | 1.25/1.6 | 1.25/1.6 | 1.25/1.6 | 1.25/1.6 | 1.25/1.6 | 1.25/1.6 | 1.25/1.6 |
Steam Temperature | ℃ | 193/204 | 193/204 | 193/204 | 193/204 | 193/204 | 193/204 | 193/204 |
Feed Water Temperature | ℃ | 20 | 20 | 20 | 20 | 20 | 20 | 60 |
Thermal Efficiency | / | ≥82 | ||||||
Fuel | / | Biomass particles | ||||||
Fuel Consumption | Kg/h | 176.6 | 352.3 | 522.5 | 697 | 1044 | 1396 | 1744 |
Heating area | m2 | 39.82 | 82 | 120.2 | 174.32 | 239 | 317 | 409 |
Grate area | m2 | 1.97 | 2.7 | 4.1 | 5.43 | 6.7 | 10.2 | 13.6 |
Power consumption | Kw | 13.7 | 18 | 31.5 | 31.5 | 45 | 69.2 | 95.5 |
water volume | m3 | 4.5 | 4.68 | 5.9 | 6.3 | 11 | 13.8 | 16.5 |
Note: The fuel consumption in the table is calculated on the basis of the low calorific value of biomass particles 17084KJ/Kg (4085Kcal/Kg). If the low calorific value of biomass fuel is larger than that, the corresponding fuel consumption will be more economical than that in the table.
Shape and Interface Dimensions of DZH Series Hand-fired Biomass Steam Boilers
Type Item | DZH1 | DZH2 | DZH3 | DZH4 | DZH6 | DZH8 | DZH10 | ||
Rated Steam Capacity | t/h | 1 | 2 | 3 | 4 | 6 | 8 | 10 | |
Host Transport Dimension | L | mm | 4300 | 5140 | 5630 | 5920 | 6200 | 6800 | 7500 |
W | mm | 1900 | 2500 | 2700 | 2700 | 2960 | 3400 | 3400 | |
H | mm | 2900 | 3100 | 3300 | 3430 | 3580 | 3600 | 3700 | |
Host Transport Weight | / | t | 13.6 | 18 | 23 | 25.3 | 31 | 34 | 39 |
Main Steam Valve Pipe Diameter | DN | mm | 65 | 80 | 100 | 100 | 125 | 150 | 150 |
Feed Water Valve | DN | mm | 40 | 40 | 40 | 40 | 50 | 50 | 50 |
Safety Valve Diameter | DN | mm | 2×40 | 2×50 | 2×50 | 2×50 | 50/80 | 2×80 | 2×80 |
Drain Valve Pipe Diameter | DN | mm | 3×40 | 3×40 | 3×40 | 3×40 | 3×40 | 3×40 | 3×40 |
Chimney Diameter | φ | mm | 280 | 350 | 410 | 410 | 530 | 720 | 750 |
Remarks: We will reserve rights to change the above mentioned data due to continuous policy transformation and product improvement.