Product Features
1. High safety:
Feed water is controlled by a computer and feeds water automatically. Equipped with water shortage, overpressure protection and other devices, safe and reliable.
2. Longevity and durability:
Professional excellent design, advanced production technology and strict quality control of boilers are the guarantee of the quality of each boiler. The normal service life of boilers is more than 20 years.
3. Environmental protection and low noise:
The original flue gas emission of the boiler is low, and the tail of the boiler is equipped with high efficiency dust collector and low noise fan, so that the flue gas emission meets the national environmental protection requirements.
4. Manufacturing specifications:
Each part of the boiler is manufactured in accordance with the national and international standards (ISO). Every production link strictly follows the advanced production technology to ensure the reliability of product quality.
5. Quality service:
Technical services, installation guidance, regular and irregular return visits to users, at any time to provide quality and perfect services, so that users can buy at ease, with comfort.
Technical Parameters
Main Technical Parameters of DZH Series Biomass Steam Boiler
Item | Unit | DZH1 | DZH2 | DZH3 | DZH4 | DZH6 | DZH8 | DZH10 |
Steam Capacity | t/h | 1 | 2 | 3 | 4 | 6 | 8 | 10 |
Working Pressure | MPa | 1.25/1.6 | 1.25/1.6 | 1.25/1.6 | 1.25/1.6 | 1.25/1.6 | 1.25/1.6 | 1.25/1.6 |
Steam Temperature | ℃ | 193/204 | 193/204 | 193/204 | 193/204 | 193/204 | 193/204 | 193/204 |
Feed Water Temperature | ℃ | 20 | 20 | 20 | 20 | 20 | 20 | 60 |
Thermal Efficiency | / | ≥82 | ||||||
Fuel | / | Biomass particles | ||||||
Fuel Consumption | Kg/h | 176.6 | 352.3 | 522.5 | 697 | 1044 | 1396 | 1744 |
Heating area | m2 | 39.82 | 82 | 120.2 | 174.32 | 239 | 317 | 409 |
Grate area | m2 | 1.97 | 2.7 | 4.1 | 5.43 | 6.7 | 10.2 | 13.6 |
Power consumption | Kw | 13.7 | 18 | 31.5 | 31.5 | 45 | 69.2 | 95.5 |
water volume | m3 | 4.5 | 4.68 | 5.9 | 6.3 | 11 | 13.8 | 16.5 |
Note: The fuel consumption in the table is calculated on the basis of the low calorific value of biomass particles 17084KJ/Kg (4085Kcal/Kg). If the low calorific value of biomass fuel is larger than that, the corresponding fuel consumption will be more economical than that in the table.
Shape and Interface Dimensions of DZH Series Hand-fired Biomass Steam Boilers
Type Item | DZH1 | DZH2 | DZH3 | DZH4 | DZH6 | DZH8 | DZH10 | ||
Rated Steam Capacity | t/h | 1 | 2 | 3 | 4 | 6 | 8 | 10 | |
Host Transport Dimension | L | mm | 4300 | 5140 | 5630 | 5920 | 6200 | 6800 | 7500 |
W | mm | 1900 | 2500 | 2700 | 2700 | 2960 | 3400 | 3400 | |
H | mm | 2900 | 3100 | 3300 | 3430 | 3580 | 3600 | 3700 | |
Host Transport Weight | / | t | 13.6 | 18 | 23 | 25.3 | 31 | 34 | 39 |
Main Steam Valve Pipe Diameter | DN | mm | 65 | 80 | 100 | 100 | 125 | 150 | 150 |
Feed Water Valve | DN | mm | 40 | 40 | 40 | 40 | 50 | 50 | 50 |
Safety Valve Diameter | DN | mm | 2×40 | 2×50 | 2×50 | 2×50 | 50/80 | 2×80 | 2×80 |
Drain Valve Pipe Diameter | DN | mm | 3×40 | 3×40 | 3×40 | 3×40 | 3×40 | 3×40 | 3×40 |
Chimney Diameter | φ | mm | 280 | 350 | 410 | 410 | 530 | 720 | 750 |
Remarks: We will reserve rights to change the above mentioned data due to continuous policy transformation and product improvement.