Product Features
1. Clean and convenient:
The installation of more than one ash treatment plant can remove ash efficiently and in a timely manner, avoid operating obstacles, avoid reducing the thermal efficiency of the boiler ash and ensure the stability of the boiler load.
2. High security:
The water supply is controlled by the computer and is provided automatically. It is safe and reliable to deal with water shortages, protection against overload and other devices.
3. Shelf -life and shelf -life:
Excellent technical design, advanced production technology and strict quality control ensure the quality of each boiler; the normal life of the boiler exceeds the 20 -year period.
4. Environmental protection and low noise:
In the initial phase, the exhaust gas emission of the boiler is low and the tail of the boiler is equipped with an efficient dust collector and a low noise fan.
5. Processing specifications:
Each part of the boiler shall be produced in accordance with national and international standards (ISO).Ensure product quality assurance.
6.Good service:
Technical services, installation instructions, regular and informal user visits at any time in order to provide users with high -quality and complete services so that users can buy safe and comfortable services.
Technical Parameters
Main Technical Parameters of DZH Series Biomass Steam Boiler
Item | Unit | DZH1 | DZH2 | DZH3 | DZH4 | DZH6 | DZH8 | DZH10 |
Steam Capacity | t/h | 1 | 2 | 3 | 4 | 6 | 8 | 10 |
Working Pressure | MPa | 1.25/1.6 | 1.25/1.6 | 1.25/1.6 | 1.25/1.6 | 1.25/1.6 | 1.25/1.6 | 1.25/1.6 |
Steam Temperature | ℃ | 193/204 | 193/204 | 193/204 | 193/204 | 193/204 | 193/204 | 193/204 |
Feed Water Temperature | ℃ | 20 | 20 | 20 | 20 | 20 | 20 | 60 |
Thermal Efficiency | / | ≥82 | ||||||
Fuel | / | Biomass particles | ||||||
Fuel Consumption | Kg/h | 176.6 | 352.3 | 522.5 | 697 | 1044 | 1396 | 1744 |
Heating area | m2 | 39.82 | 82 | 120.2 | 174.32 | 239 | 317 | 409 |
Grate area | m2 | 1.97 | 2.7 | 4.1 | 5.43 | 6.7 | 10.2 | 13.6 |
Power consumption | Kw | 13.7 | 18 | 31.5 | 31.5 | 45 | 69.2 | 95.5 |
water volume | m3 | 4.5 | 4.68 | 5.9 | 6.3 | 11 | 13.8 | 16.5 |
Note: The fuel consumption in the table is calculated on the basis of the low calorific value of biomass particles 17084KJ/Kg (4085Kcal/Kg). If the low calorific value of biomass fuel is larger than that, the corresponding fuel consumption will be more economical than that in the table.
Shape and Interface Dimensions of DZH Series Hand-fired Biomass Steam Boilers
Type Item | DZH1 | DZH2 | DZH3 | DZH4 | DZH6 | DZH8 | DZH10 | ||
Rated Steam Capacity | t/h | 1 | 2 | 3 | 4 | 6 | 8 | 10 | |
Host Transport Dimension | L | mm | 4300 | 5140 | 5630 | 5920 | 6200 | 6800 | 7500 |
W | mm | 1900 | 2500 | 2700 | 2700 | 2960 | 3400 | 3400 | |
H | mm | 2900 | 3100 | 3300 | 3430 | 3580 | 3600 | 3700 | |
Host Transport Weight | / | t | 13.6 | 18 | 23 | 25.3 | 31 | 34 | 39 |
Main Steam Valve Pipe Diameter | DN | mm | 65 | 80 | 100 | 100 | 125 | 150 | 150 |
Feed Water Valve | DN | mm | 40 | 40 | 40 | 40 | 50 | 50 | 50 |
Safety Valve Diameter | DN | mm | 2×40 | 2×50 | 2×50 | 2×50 | 50/80 | 2×80 | 2×80 |
Drain Valve Pipe Diameter | DN | mm | 3×40 | 3×40 | 3×40 | 3×40 | 3×40 | 3×40 | 3×40 |
Chimney Diameter | φ | mm | 280 | 350 | 410 | 410 | 530 | 720 | 750 |
Remarks: We will reserve rights to change the above mentioned data due to continuous policy transformation and product improvement.