Product Discription
Number of kiln is 1600 mm.The side of the kiln housing is equipped with a water cooling wall and a radioactive water heating surface.Below 1600.Important.A process is introduced t of a melting furnace.
Body structure, water -cooling wall panel 160, interior solution 160, 1600 *14, police 57 *3, 159 *6, 133 *6, 130, before and after police use, high degree of combustion.
Product Features
1. Easy installation:
Boilers are usually equipped with fast loading equipment to facilitate transportation and installation of equipment, thus greatly shortening the construction period and service life. User curiosity
2. Reliability of use:
Boilers are fully equipped with open water circulation.
3. Technical services:
The drawer in front of the pot is easy to open and the staff can easily and clearly check, which is a good condition for correct handling.
4. low noise:
The boiler has low temperature gas, high efficiency scrubber, low noise tail fan and other performance, which meets the national environmental protection standards. Clear requirements.
5.Total combustion
Reasonable arrangement of furnace lining, smooth water circulation, timely cooling.
Technical Parameters
Main Technical Parameters of DZL Series Biomass Hot Water Boiler
Item | Unit | DZL0.7 | DZL1.4 | DZL2.1 | DZL2.8 | DZL4.2 | DZL5.6 | DZL7 |
Thermal Power | MW | 0.7 | 1.4 | 2.1 | 2.8 | 4.2 | 5.6 | 7 |
Outlet Pressure | MPa | 1.0 | 1.0 | 1.0 | 1.0 | 1.0/1.25 | 1.0/1.25 | 1.0/1.25 |
Outlet Temperature | ℃ | 95 | 95 | 95 | 95 | 95/115 | 95/115 | 95/115 |
Feed Water Temperature | ℃ | 70 | 70 | 70 | 70 | 70 | 70 | 70 |
Thermal Efficiency | / | ≥83% | ||||||
Fuel | / | Biomass particles | ||||||
Fuel Consumption | Kg/h | 174.3 | 348.6 | 517 | 687.2 | 1024 | 1374.3 | 1708 |
Heating area | m2 | 35.2 | 79.8 | 114.2 | 168 | 207.6 | 300.5 | 391 |
Grate area | m2 | 1.97 | 3.2 | 4.8 | 5.5 | 7.04 | 11.7 | 13.6 |
Power consumption | Kw | 18 | 26 | 31.5 | 34 | 62.4 | 76.4 | 87.2 |
water volume | m3 | 5.1 | 5.58 | 6.95 | 9.3 | 14 | 17.8 | 20.5 |
Note: the fuel consumption in the table is calculated on the basis of the low calorific value of biomass particles 17084KJ/Kg (4085Kcal/Kg). If the low calorific value of biomass fuel is larger than this value, the corresponding fuel consumption will be more economical than the value in the table.
Item | Unit | DZL0.7 | DZL1.4 | DZL2.1 | DZL2.8 | DZL4.2 | DZL5.6 | DZL7 | |
Thermal Power | MW | 0.7 | 1.4 | 2.1 | 2.8 | 4.2 | 5.6 | 7 | |
Transport Dimension
| L | mm | 5100 | 6140 | 6330 | 6880 | 7290 | 7800 | 8500 |
W | mm | 2200 | 2600 | 2700 | 2700 | 3190 | 3400 | 3400 | |
H | mm | 2900 | 3300 | 3300 | 3300 | 3700 | 3700 | 3700 | |
Mainframe Transport Weight | / | t | 15 | 18 | 24 | 27 | 31 | 33 | 41 |
Outlet Water Valve | DN | mm | 80 | 100 | 125 | 125 | 150 | 200 | 200 |
Feed Water Valve | DN | mm | 80 | 100 | 125 | 125 | 150 | 200 | 200 |
Safety Valve Diameter | DN | mm | 1*32 | 1*50 | 2*40 | 2*40 | 2*50 | 2*50 | 2*50/80 |
Drain Valve Pipe Diameter | DN | mm | 3*40 | 3*40 | 3*40 | 3*40 | 3*40 | 3*40 | 3*40 |
Chimney Diameter | φ | mm | 280 | 350 | 410 | 410 | 530 | 720 | 750 |
Remarks: We will reserve rights to change the above mentioned data due to continuous policy transformation and product improvement.