Product Discription
The furnace board is 1600 mm. The side of the winning body is equipped with a cooling wall of water and a surface treatment of radiation water. Plates under 1600.Important.The melting furnace process is introduced.
Body configuration, water -cooled panel 160, internal solution 160, 1600, 1600 *14, police 57 *3, 159 *6, 133 *6, 130, before and after police use, high combustion rate.
Product Features
1. Easy to install:
Boilers are usually equipped with a quick installation device that facilitates the transport and installation of equipment, significantly shortens the building cycle and provides comfort to users.
2. Operational reliability:
Cooler equipment is complete, water circulation is smooth, cooling work is done on time.
3. Maintenance:
It is easy to open the drawer in front of the boiler and the staff can control it easily and clearly. These are good conditions for proper handlin
4. Total combustion
The coating measure is reasonable, the water volume is even and the cooling is timely.
5. Duration and durability:
Boiler design is excellent, production facilities are advanced and quality control is rigorous.
6. Low noise level:
Boilers have characteristics such as low temperature chamber gas emissions, high efficiency scrubbers, low -tailed vacuum cleaners, etc., which meet national environmental protection requirements.
.
Technical Parameters
Main Technical Parameters of DZL Series Biomass Hot Water Boiler
Item | Unit | DZL0.7 | DZL1.4 | DZL2.1 | DZL2.8 | DZL4.2 | DZL5.6 | DZL7 |
Thermal Power | MW | 0.7 | 1.4 | 2.1 | 2.8 | 4.2 | 5.6 | 7 |
Outlet Pressure | MPa | 1.0 | 1.0 | 1.0 | 1.0 | 1.0/1.25 | 1.0/1.25 | 1.0/1.25 |
Outlet Temperature | ℃ | 95 | 95 | 95 | 95 | 95/115 | 95/115 | 95/115 |
Feed Water Temperature | ℃ | 70 | 70 | 70 | 70 | 70 | 70 | 70 |
Thermal Efficiency | / | ≥83% | ||||||
Fuel | / | Biomass particles | ||||||
Fuel Consumption | Kg/h | 174.3 | 348.6 | 517 | 687.2 | 1024 | 1374.3 | 1708 |
Heating area | m2 | 35.2 | 79.8 | 114.2 | 168 | 207.6 | 300.5 | 391 |
Grate area | m2 | 1.97 | 3.2 | 4.8 | 5.5 | 7.04 | 11.7 | 13.6 |
Power consumption | Kw | 18 | 26 | 31.5 | 34 | 62.4 | 76.4 | 87.2 |
water volume | m3 | 5.1 | 5.58 | 6.95 | 9.3 | 14 | 17.8 | 20.5 |
Note: the fuel consumption in the table is calculated on the basis of the low calorific value of biomass particles 17084KJ/Kg (4085Kcal/Kg). If the low calorific value of biomass fuel is larger than this value, the corresponding fuel consumption will be more economical than the value in the table.
Item | Unit | DZL0.7 | DZL1.4 | DZL2.1 | DZL2.8 | DZL4.2 | DZL5.6 | DZL7 | |
Thermal Power | MW | 0.7 | 1.4 | 2.1 | 2.8 | 4.2 | 5.6 | 7 | |
Transport Dimension
| L | mm | 5100 | 6140 | 6330 | 6880 | 7290 | 7800 | 8500 |
W | mm | 2200 | 2600 | 2700 | 2700 | 3190 | 3400 | 3400 | |
H | mm | 2900 | 3300 | 3300 | 3300 | 3700 | 3700 | 3700 | |
Mainframe Transport Weight | / | t | 15 | 18 | 24 | 27 | 31 | 33 | 41 |
Outlet Water Valve | DN | mm | 80 | 100 | 125 | 125 | 150 | 200 | 200 |
Feed Water Valve | DN | mm | 80 | 100 | 125 | 125 | 150 | 200 | 200 |
Safety Valve Diameter | DN | mm | 1*32 | 1*50 | 2*40 | 2*40 | 2*50 | 2*50 | 2*50/80 |
Drain Valve Pipe Diameter | DN | mm | 3*40 | 3*40 | 3*40 | 3*40 | 3*40 | 3*40 | 3*40 |
Chimney Diameter | φ | mm | 280 | 350 | 410 | 410 | 530 | 720 | 750 |
Remarks: We will reserve rights to change the above mentioned data due to continuous policy transformation and product improvement.