Product Discription
LSS Oil Fired Steam Generator
The LSS Oil Vertical Vapour Generator receives the vertical pipe structure. There are two lower rings and a special cylinder for the cartridge between the top and bottom housing pipes, which make up three combustion gases. to swell and burn.
For water heaters and condensers, the thermal efficiency can reach 93% and 100%. With steam -water separators and external steam -water separators, it can provide high -quality dry steam, save fuel, reduce the system scale and extend service life.
1. Easy Maintenance:
Inspection doors are set at the bottom to check and clean the furnace interior for easy maintenance.
2. in line with environmental protection:
high quality and reliable burner, so that fuel can be fully burned, while greatly reducing harmful emissions in flue gas. The test results of relevant departments show that the fuel (gas) steam generator meets the national environmental protection requirements.
3. The amount of evaporation can be increased.:
Steam generators can be modularized into several units (unlimited number) and controlled by computer.Total evaporation can be added freely.The relevant components of steam generator (including water treatment, water pump, burner, electronic control box and main valve instruments) are already in the factory.
4. Installation is an integral whole:
It can be connected with water, electricity and steam pipes on site, which saves time and effort in installation.
5. Reliable accessories:
matching burners, control boxes, water treatment, and valves, pumps are made of domestic high-quality equipment. The matching equipment can ensure the safe and reliable operation of the steam generator and improve the overall quality of the steam generator.
Technical Parameters
Main Technical Reference for Fuel (Gas) Steam Generator | ||||||
Item Unit | LSS0.05 | LSS0.1 | LSS0.15 | LSS0J2 | ||
Rated evaporation | Kg/h | 50 | 100 | 150 | 200 | |
Rated Pressure PTEPREppoPressure | MPa | 0.4/0.7 | ||||
Rated steam temperature | c | 151/171 | ||||
Rated feed water temperature | °C | 20 | ||||
Evaporator efficiency | / | >92% | ||||
Applicable Fuel | / | Gas light oil | ||||
Theoretical fuel consumption | Gas | NM3/h | 4 | 8 | 12 | 16 |
Light Oil | Kg/h | 3.3 | 6.5 | 9.8 | 13 | |
Gas supply pressure | mbar | 60- 100 | ||||
water volume | L | <30 |
Note: The fuel consumption in the table is based on the low calorific value of biomass particles 17084 KJ/Kg (4085 Kcal/Kg).Calculations show that if the low calorific value of biomass fuel is higher than that, the corresponding fuel consumption will be more economical than the values in the table.
Configuration and Interface Size of Fuel (Gas) Steam Generator | ||||||
Item Unit | LSS0.05 | LSSO.l | LSS0.15 | LSS0.2 | ||
Outward Size of Main Engine
(length * width * height) | / | mm | 620*620*830 | 690*690*968 | 750*750*1130 | 800*800*1286 |
Transport Dimension
| / | mm | 206 | 252 | 303 | 350 |
Mainframe Transport Weight | DN | mm | G 1/2- | Gl' | Gl" | G 1* |
Main Steam Valve Pipe Diameter | DN | mm | Gl/2" | Gl/2- | Gl/2- | Gl/2° |
Feed Water Valve | DN | mm | G1 1/4” | G11/4- | G11/4- | G11/4- |
Safety Valve Diameter | DN | mm | Gf | GF | Gl" | Gl" |
Drain Valve Pipe Diameter | DN | mm | 133 | 133 | 159 | 159 |
Remarks: We will reserve rights to change the above mentioned data due to continuous policy transformation and product improvement.