Product Discription
LSS Oil Fired Steam Generator
Vertical steam power LSS receives vertical pipe structure. Between the two lower rings and a special tube between the upper and lower protective tube protective tube formed three gases. Zoom and burn
For radiators and condensers thermal efficiency can be 93% and 100%. Use steam - water separator and an external steam - water separators provide high quality dry pair, save fuel, reduce the size of the system and prolong life.
1. Ease of maintenance:
Doors for inspection arranged at the bottom for inspection and cleaning the inside of the furnace for easy maintenance.
2. meet environmental requirements:
Qualitative and reliable burner completely combusted fuel, but significantly reduces harmful emissions of waste. Test results of various departments show that the power of steam (gas) steam meets the national environmental protection requirements.
3. The amount of evaporation can be increased:
The steam engine can be designed with several units (without limitation) and can be controlled by a computer. You can add a shared task. Relevant parts of the steam energy (including water purification, pumps, burners, electric control panels and main valve blocks) are already being produced at the factory.
4. The installation is completed:
It can connect water, electricity and steam pipes on the spot, saving installation time and effort.
5. Reliable accessories:
Support vodka, control box, water purification and valves, pumps are equipped with the national high-quality equipment. The support system provides a safe and reliable operation of the steam energy and improves the overall quality of the steam power.
Technical Parameters
Main Technical Reference for Fuel (Gas) Steam Generator | ||||||
Item Unit | LSS0.05 | LSS0.1 | LSS0.15 | LSS0J2 | ||
Rated evaporation | Kg/h | 50 | 100 | 150 | 200 | |
Rated Pressure PTEPREppoPressure | MPa | 0.4/0.7 | ||||
Rated steam temperature | c | 151/171 | ||||
Rated feed water temperature | °C | 20 | ||||
Evaporator efficiency | / | >92% | ||||
Applicable Fuel | / | Gas light oil | ||||
Theoretical fuel consumption | Gas | NM3/h | 4 | 8 | 12 | 16 |
Light Oil | Kg/h | 3.3 | 6.5 | 9.8 | 13 | |
Gas supply pressure | mbar | 60- 100 | ||||
water volume | L | <30 |
Note: The fuel consumption in the table is based on the low calorific value of biomass particles 17084 KJ/Kg (4085 Kcal/Kg).Calculations show that if the low calorific value of biomass fuel is higher than that, the corresponding fuel consumption will be more economical than the values in the table.
Configuration and Interface Size of Fuel (Gas) Steam Generator | ||||||
Item Unit | LSS0.05 | LSSO.l | LSS0.15 | LSS0.2 | ||
Outward Size of Main Engine
(length * width * height) | / | mm | 620*620*830 | 690*690*968 | 750*750*1130 | 800*800*1286 |
Transport Dimension
| / | mm | 206 | 252 | 303 | 350 |
Mainframe Transport Weight | DN | mm | G 1/2- | Gl' | Gl" | G 1* |
Main Steam Valve Pipe Diameter | DN | mm | Gl/2" | Gl/2- | Gl/2- | Gl/2° |
Feed Water Valve | DN | mm | G1 1/4” | G11/4- | G11/4- | G11/4- |
Safety Valve Diameter | DN | mm | Gf | GF | Gl" | Gl" |
Drain Valve Pipe Diameter | DN | mm | 133 | 133 | 159 | 159 |
Remarks: We will reserve rights to change the above mentioned data due to continuous policy transformation and product improvement.