Product Discription
LSS Oil Fired Steam Generator
The vertical steam supplied by LSS accepts the vertical tube structure. A special protection tube between the two lower rings and the upper and lower protection tubes produces three gases. Zoom in and burn
For heat sinks and capacitors, the thermal efficiency can be 93% to 100%. Use steam - water separator and external steam. Water dispensers provide high-quality dry fuel savings, reduce system size and extend service life.
1. Easy to maintain:
There is an inspection door underneath for inspection and cleaning of the interior of the oven for easy maintenance.
2. Meet the environmental requirements:
Efficient and reliable burners burn all fuels but greatly reduce the emission of hazardous wastes. Test results of various departments show that gas (gas) vapor meets the environmental protection requirements of the environment.
3. The amount of evaporation can be increased:
The steam engine can be designed by many units (without restrictions) and can be controlled by a computer. You can add shared tasks. The plant produces a significant amount of steam energy (water purification, pumps, burners, electronic control panels and main valve blocks).
4. Installation complete:
Water, electricity and steam pipes can be connected to the site, saving time and installation effort.
5. Reliable accessories:
Provide vodka, control box, water purifier and valve, national pump quality equipment support. The support system provides safe and reliable steam operation that enables and improves the quality of steam power.
Technical Parameters
Main Technical Reference for Fuel (Gas) Steam Generator | ||||||
Item Unit | LSS0.05 | LSS0.1 | LSS0.15 | LSS0J2 | ||
Rated evaporation | Kg/h | 50 | 100 | 150 | 200 | |
Rated Pressure PTEPREppoPressure | MPa | 0.4/0.7 | ||||
Rated steam temperature | c | 151/171 | ||||
Rated feed water temperature | °C | 20 | ||||
Evaporator efficiency | / | >92% | ||||
Applicable Fuel | / | Gas light oil | ||||
Theoretical fuel consumption | Gas | NM3/h | 4 | 8 | 12 | 16 |
Light Oil | Kg/h | 3.3 | 6.5 | 9.8 | 13 | |
Gas supply pressure | mbar | 60- 100 | ||||
water volume | L | <30 |
Note: The fuel consumption in the table is based on the low calorific value of biomass particles 17084 KJ/Kg (4085 Kcal/Kg).Calculations show that if the low calorific value of biomass fuel is higher than that, the corresponding fuel consumption will be more economical than the values in the table.
Configuration and Interface Size of Fuel (Gas) Steam Generator | ||||||
Item Unit | LSS0.05 | LSSO.l | LSS0.15 | LSS0.2 | ||
Outward Size of Main Engine
(length * width * height) | / | mm | 620*620*830 | 690*690*968 | 750*750*1130 | 800*800*1286 |
Transport Dimension
| / | mm | 206 | 252 | 303 | 350 |
Mainframe Transport Weight | DN | mm | G 1/2- | Gl' | Gl" | G 1* |
Main Steam Valve Pipe Diameter | DN | mm | Gl/2" | Gl/2- | Gl/2- | Gl/2° |
Feed Water Valve | DN | mm | G1 1/4” | G11/4- | G11/4- | G11/4- |
Safety Valve Diameter | DN | mm | Gf | GF | Gl" | Gl" |
Drain Valve Pipe Diameter | DN | mm | 133 | 133 | 159 | 159 |
Remarks: We will reserve rights to change the above mentioned data due to continuous policy transformation and product improvement.