LSH Series 0.2 tons per hour Normal Pressure Biomass Fired Steam Boiler
Product Discription
LSH Series Vertical Biomass Fired Steam Boiler
The LSH0.9-0.7-T boiler is a vertical stream-time boiler material, and an inlet device is installed at the bottom of the furnace. The boiler is a horizontal pipe located in the assembling chamber and in the back part of the furnace, its main function is to increase the temperature of the boiler and improve the thermal performance. RITA is also equipped with an economizer, so that high heat flow is used.
After fueling the ceilings, the cement is made directly from the furnace and horizontal pipes, allowing the chimney to move to the chimney stack, which is economically affected by the fireplace and the chimney. In the pumped cleaning machine. After the soil is exhausted, the chimney enters the chimney and the final clean pipe is discharged through the chimney into the atmosphere. The sutural part is inserted into the right hole through the right side of the hole, and the artificial shell is removed through the wall door. This section covers the lower part of the downstream flow of the chimney, which reduces artificial flow from the lower and ramp pools to clear space.
Product Features
1. Easy to install
Usually Baile is a fast installation factor, which is easy to replicate and install on-site, which greatly increases the duration of construction, saves installation costs, and enables boilers to be produced in time.
2. Reliable operation:
The boiler is reasonably well-adjusted to the heating surface, the water circulation is soft, and every heat level is timely, which effectively ensures the safe operation of the boiler.
3. Easy maintenance
To access the inspection, the boiler mask is provided with an inspection hole. It is easy to open in front of the bowler, and staff can easily and clearly check the smoke box, which provides a good bet for proper handling.
4. Fully Explosed:
With secondary air and a proper furnace design, you can burn the oil completely and remove black smoke.
5. Proper grade:
Boiler Gate accepts two-sided ventilation, and dust removal technology naturally eliminates boiler alignment, avoiding air leakage, oil leakage, uneven ventilation, easier operation, and clearer advantages than ordinary gate. آهن.
6. The method of soil removal is simple:
The ash accumulation can be arranged with a hole in the drill hole, which allows the ash to be cut, to remove the ash, to avoid the operation troubles and to reduce the movement of the toes, to increase the load and load of the boiler. To ensure stability.
Technical Parameters
Item | Unit | LSH0.1 | LSH0.2 | LSH0.3 | LSH0.5 | LSH0.7 | LSH1 |
Steam Capacity | t/h | 0.1 | 0.2 | 0.3 | 0.5 | 0.7 | 1 |
Working Pressure | MPa | 0.4 | 0.4 | 0.4/0.7 | 0.4/0.7 | 0.4/0.7 | 0.4/0.7 |
Steam Temperature | ℃ | 151 | 151 | 151/171 | 151/171 | 151/171 | 151/171 |
Feed Water Temperature | ℃ | 20 | 20 | 20 | 20 | 20 | 20 |
Thermal Efficiency | / | ≥81 | |||||
Fuel | / | Biomass particles | |||||
Fuel Consumption | Kg/h | 18.39 | 36.23 | 53.8 | 89.76 | 125.1 | 178.7 |
Heating area | m2 | 9.5 | 17.27 | 20.01 | 30.6 | 33.93 | 59.93 |
Grate area | m2 | 0.26 | 0.36 | 0.48 | 0.95 | 1.13 | 1.47 |
Power consumption | Kw | 4.5 | 4.5 | 5.5 | 9.5 | 11.5 | 11.5 |
water volume | m3 | 0.43 | 0.58 | 0.73 | 1.25 | 1.81 | 2.5 |
Note: the fuel consumption in the table is calculated on the basis of the low calorific value of biomass particles 17084KJ/Kg (4085Kcal/Kg). If the low calorific value of biomass fuel is larger than this value, the corresponding fuel consumption will be more economical than the value in the table.
External and Interface Dimension of SZL Biomass steam boiler
Item | Unit | LSH0.1 | LSH0.2 | LSH0.3 | LSH0.5 | LSH0.7 | LSH1 | |
Steam Capacity | t/h | 0.1 | 0.2 | 0.3 | 0.5 | 0.7 | 1 | |
Transport Dimension
|
L | mm | 810 | 910 | 1020 | 1320 | 1420 | 1620 |
H | mm | 2590 | 2900 | 3200 | 3680 | 3870 | 4380 | |
Maximum Transport Weight | / | t | 0.72 | 0.98 | 1.6 | 2.88 | 3.67 | 4.8 |
Main Steam Valve Pipe Diameter | DN | mm | 32 | 32 | 40 | 50 | 50 | 50 |
Feed Water Valve | DN | mm | 25 | 25 | 25 | 25 | 25 | 32 |
Safety Valve Diameter | DN | mm | 40 | 40 | 40 | 40 | 2*40 | 2*40 |
Drain Valve Pipe Diameter | DN | mm | 40 | 40 | 40 | 40 | 40 | 40 |
Chimney Diameter | φ | mm | 180 | 220 | 280 | 280 | 280 | 280 |
Remarks: We will reserve rights to change the above mentioned data due to continuous policy transformation and product improvement.