Product Discription
WNS Series Horizontal Biomass Gas Fired Steam Boiler
Installation and installation of a WNS-style biogas gas oven. The 3D water heater is equipped with water heater, high pressure gas stove and a second fire extinguisher. Remove the smoke and smoke from behind. Add air. The boilers have front and front covers for a smoke box for easy maintenance.
Product Features
1. Easy to install:
Typically, water heaters are easy to transport and install on site, reduce construction time, save on installation costs, and can be used in severe weather.
2. Operations based on operations:
The boat is fully air-conditioned, air-conditioned, and quickly cooled to ensure a safe working environment.
3. Power at Work:
Canoes can arrange and register properly. Opening the trunk in front of the box is very good, the staff can save the box and show the proper conditions for proper removal.
4. Complete summary:
Modern air conditioning and effective heat control eliminate dryness of smoke and black smoke.
5. Effective Grid:
The double glue air conditioner has a removable air filter designed for water, natural, drainage, dehydration and ease of operation, and has far greater advantages than conventional grills.
6. Simple Ash Removal Application:
Many types of pores may be formed in the oil ashes, and the ashes will be removed over time, and air-conditioning operations may be obstructed by compressed air, obstructing the destruction of the action. Constant due to excessive dust.
Technical Parameters
Main Technical parameters of WNS Biomass Gas-fired Steam Boiler
WNS0.5 | WNS1 | WNS2 | WNS3 | WNS4 | WNS6 | |||
Steam Capacity | t/h | 0.5 | 1 | 2 | 3 | 4 | 6 | |
Working Pressure | MPa | 1.0 | 1.25 | 1.25 | 1.25 | 1.25 | 1.25 | |
Steam Temperature | ℃ | 184 | 193 | 193 | 193 | 193 | 193 | |
Feed Water Temperature | ℃ | 20 | 20 | 20 | 20 | 20 | 20 | |
Biomass Efficiency | / | ≥88% | ||||||
Gas efficiency | / | ≥92% | ||||||
Fuel | / | Biomass particles, natural gas, liquefied gas, city gas, producer gas, light oil, etc. | ||||||
Fuel Consumption | Biomass particles | Kg/h | 89 | 177 | 355 | 532 | 711 | 1059 |
Natural gas | NM3/h | 38 | 75 | 149 | 223 | 298 | 446 | |
Liquefied gas | Kg/h | 30 | 60 | 119 | 177 | 237 | 359 | |
City gas | NM3/h | 81 | 160 | 318 | 473 | 634 | 950 | |
Producer gas | NM3/h | 258 | 517 | 1038 | 1541 | 2063 | 3111 | |
Light oil | Kg/h | 32 | 63 | 126 | 185 | 247 | 370 | |
Gas Feed pressure | Natural Gas | mbar | 50-100 | 50-100 | 50-100 | 50-100 | 50-100 | 50-100 |
City Gas | mbar | 70-200 | 70-200 | 70-200 | 70-200 | 70-200 | 70-200 | |
Running water volume | M3 | 1.2 | 1.96 | 3.4 | 4.98 | 5.63 | 7.32 |
Note: the fuel consumption in the table is low calorific value 17084KJ/Kg (4085Kcal/Kg) for biomass particles, 35588KJ/NM3 (8500Kcal/NM3) for natural gas, and 45998KJ/Kg (11000Kcal/Kg) for liquefied gas. Low calorific value of city gas 16750KJ/NM3 (4000Kcal/NM3), low calorific value of furnace gas 5650KJ/NM3 (1351Kcal/NM3), low calorific value of light oil 42915KJ/K G (10260Kcal/Kg) calculation
External and Interface Dimension of WNS Biomass Gas Steam Boiler
Shape and Interface Dimensions of WNS Biomass Gas Steam boilers | ||||||||
Item | Unit | WNS0.5 | WNS1 | WNS2 | WNS3 | WNS4 | WNS6 | |
Transport Dimension (L*W*H) | / | mm | 3220*1550*1720 | 3730*1790*2010 | 4240*2140*2182 | 4243*2453*2488 | 4473*2470*2736 | 4530*3010*3090 |
Mainframe transport weight | / | t | 3.2 | 5.3 | 8.5 | 10.5 | 13 | 17 |
Main Steam Valve Pipe Diameter | DN | mm | 40 | 65 | 80 | 100 | 100 | 125 |
Feed Water Valve | DN | mm | 25 | 40 | 40 | 40 | 40 | 50 |
Safety Valve Diameter | DN | mm | 40 | 2*50 | 2*50 | 2*50 | 2*50 | 2*80 |
Drain Valve Pipe Diameter | DN | mm | 40 | 40 | 40 | 40 | 40 | 40 |
Chimney Diameter | φ | mm | 250 | 280 | 350 | 400 | 400 | 600 |
Remarks: We will reserve rights to change the above mentioned data due to continuous policy transformation and product improvement.