Product Discription
WNS Series Horizontal Biomass Gas Fired Steam Boiler
Installation and installation of WNS biomass horizontal gas boiler. The indoor 3D water heater comes with a water heater, high pressure cooker and second fire pit. Remove the smoke and smoke from the back. Add air. The boiler is equipped with front and rear smoke box covers for easy maintenance.
Product Features
1. Easy Installation:
As a rule, water heaters are easy to transport and install, reducing construction time, saving on installation costs and weather in harsh weather conditions.
2. Operation-based operation:
The ship has full air conditioning, air conditioning and quick cooling water to ensure safe working atmosphere.
3. Work force:
Canoes can be arranged and registered properly. Opening the trunk to the front of the box is very good, the staff can keep the box open and show ideal conditions for proper disposal.
4. Full Summary:
Modern air conditioning and efficient heat management eliminates smoke and black smoke.
5. Effective Networking:
The double glazed air filter has a removable air filter, designed for natural waterproofing, drainage, lack of air and simplicity of operation and has significant advantages over conventional grills.
6. Easy application of ash removal:
An ashes of oil may form a plurality of holes, and the ash will evaporate as time goes on, and the action of the air conditioner may be hampered by compressed air, thereby preventing performance degradation. Stable due to excessive dust.
Technical Parameters
Main Technical parameters of WNS Biomass Gas-fired Steam Boiler
WNS0.5 | WNS1 | WNS2 | WNS3 | WNS4 | WNS6 | |||
Steam Capacity | t/h | 0.5 | 1 | 2 | 3 | 4 | 6 | |
Working Pressure | MPa | 1.0 | 1.25 | 1.25 | 1.25 | 1.25 | 1.25 | |
Steam Temperature | ℃ | 184 | 193 | 193 | 193 | 193 | 193 | |
Feed Water Temperature | ℃ | 20 | 20 | 20 | 20 | 20 | 20 | |
Biomass Efficiency | / | ≥88% | ||||||
Gas efficiency | / | ≥92% | ||||||
Fuel | / | Biomass particles, natural gas, liquefied gas, city gas, producer gas, light oil, etc. | ||||||
Fuel Consumption | Biomass particles | Kg/h | 89 | 177 | 355 | 532 | 711 | 1059 |
Natural gas | NM3/h | 38 | 75 | 149 | 223 | 298 | 446 | |
Liquefied gas | Kg/h | 30 | 60 | 119 | 177 | 237 | 359 | |
City gas | NM3/h | 81 | 160 | 318 | 473 | 634 | 950 | |
Producer gas | NM3/h | 258 | 517 | 1038 | 1541 | 2063 | 3111 | |
Light oil | Kg/h | 32 | 63 | 126 | 185 | 247 | 370 | |
Gas Feed pressure | Natural Gas | mbar | 50-100 | 50-100 | 50-100 | 50-100 | 50-100 | 50-100 |
City Gas | mbar | 70-200 | 70-200 | 70-200 | 70-200 | 70-200 | 70-200 | |
Running water volume | M3 | 1.2 | 1.96 | 3.4 | 4.98 | 5.63 | 7.32 |
Note: the fuel consumption in the table is low calorific value 17084KJ/Kg (4085Kcal/Kg) for biomass particles, 35588KJ/NM3 (8500Kcal/NM3) for natural gas, and 45998KJ/Kg (11000Kcal/Kg) for liquefied gas. Low calorific value of city gas 16750KJ/NM3 (4000Kcal/NM3), low calorific value of furnace gas 5650KJ/NM3 (1351Kcal/NM3), low calorific value of light oil 42915KJ/K G (10260Kcal/Kg) calculation
External and Interface Dimension of WNS Biomass Gas Steam Boiler
Shape and Interface Dimensions of WNS Biomass Gas Steam boilers | ||||||||
Item | Unit | WNS0.5 | WNS1 | WNS2 | WNS3 | WNS4 | WNS6 | |
Transport Dimension (L*W*H) | / | mm | 3220*1550*1720 | 3730*1790*2010 | 4240*2140*2182 | 4243*2453*2488 | 4473*2470*2736 | 4530*3010*3090 |
Mainframe transport weight | / | t | 3.2 | 5.3 | 8.5 | 10.5 | 13 | 17 |
Main Steam Valve Pipe Diameter | DN | mm | 40 | 65 | 80 | 100 | 100 | 125 |
Feed Water Valve | DN | mm | 25 | 40 | 40 | 40 | 40 | 50 |
Safety Valve Diameter | DN | mm | 40 | 2*50 | 2*50 | 2*50 | 2*50 | 2*80 |
Drain Valve Pipe Diameter | DN | mm | 40 | 40 | 40 | 40 | 40 | 40 |
Chimney Diameter | φ | mm | 250 | 280 | 350 | 400 | 400 | 600 |
Remarks: We will reserve rights to change the above mentioned data due to continuous policy transformation and product improvement.