Product Discription
WNS Series Pressure Horizontal Oil Fired Hot Water Boiler
WNS series of pressure horizontal gas boilers with a gas explosion are fast loading, combustion and three -way boilers on the fire hose, which have a wet rear structure. High temperature smoke gas flushes two -way and three -way fire pipes and then releases them from the back into the atmosphere.The chimneys and capacitors, chimneys.The boiler is equipped with a sliding cover from the front and rear smoke boxes, which is suitable for maintenance.
1. Advanced control system:
Fully automatic control, users only have to press the start button, the boiler can be configured according to the program to start operation. Load control and automatic water supply are all automatic operations to meet the requirements u user.
2. In accordance with environmental requirements:
The furnace area is large, and is equipped with high quality and reliable imported burners, so that the fuel can be completely burned, and the harmful components in the combustion gases are reduced to a large extent. The inspection by the relevant departments shows that oil -fired gas boilers meet the strictest national environmental protection requirements and meet national environmental protection requirements.
3. Miscellaneous fuels applicable:
The furnace surface is large, fuel combustion is sufficient, especially for low calorific fuels such as coke oven gas, furnace gas etc. The efficiency of high calorific fuel combustion is better, such as natural gas I, liquefied gas etc.
4. Longevity and durability:
Professional design of boilers and strict quality control are the guarantee of the quality of every Yuji boilers.The service life of the boilers used is more than 20 years.
5. Easy maintenance:
front and rear movable smoke box doors, rear inspection holes can enter the oven for inspection and cleaning. Opening of Deficiencies in Ontology. Holes and handholes, structural design fully considers future maintenance.
Technical Parameters
Main Technical Parameters of WNS Series Pressure Hot Water Boilers
Item Type | WNS0.35 | WNS0.7 | WNS1.4 | WNS2.8 | WNS4.2 | WNS7 | WNS105 | WNS14 | ||
Rated Heat Efficiency | MW | 0.35 | 0.7 | 1.4 | 4.2 | 7 | 10.5 | 14 | ||
Rated Working Pressure | MPa | 0.7 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.25 | |
Rated Effluent temperature | °C | 95 | 95 | 115 | 115 | 115 | 115 | 115 | 115 | |
Return water temperature | °C | 70 | 70 | 70 | 70 | 70 | 70 | 70 | 70 | |
Efficiency | / | >96% | ||||||||
Design Fuel | / | Natural gas, liquid gas, city gas, light oil | ||||||||
Fuel Theoretical consumption | gas | NM3/h | 37 | 74 | 146 | 288 | 434 | 729 | 1080 | 1450 |
Liquid gas | Kg/h | 29 | 58 | 116 | 232 | 350 | 586 | 869 | 1149 | |
City Gas | NM3/h | 79 | 157 | 305 | 603 | 943 | 1572 | 2347 | 3141 | |
Light Oil | Kg/h | 31 | 62 | 119 | 237 | 357 | 602 | 903 | 1203 | |
Natural gas | mbar | 70-100 | 100-150 | 100-150 | 150-200 | 150-200 | 150-200 | 150-300 | 150-300 | |
City gas | mbar | 100200 | 100-200 | 100-200 | 150-200 | 150-200 | 150-200 | 150-300 | 150300 | |
Rated water circulation | M³/h | 12 | 24 | 26.67 | 53.33 | 80 | 133.33 | 200 | 266.67 | |
water capacity | M3 | 1.1 | 5.2 | 6.26 | 7.19 | 9 | 14.1 | 26.9 | 35.2 |
Note: The fuel consumption in the table is calculated by low calorific value of light oil 42915KJ/Kg (10260Kcal/Kg), low calorific value of natural gas 35588KJ/NM3 (8500Kcal/NM3), low calorific value of liquefied gas 45998KJ/Kg (11000Kcal/Kg), low calorific value of urban gas 16750K/NM3 (4000Kcal/NM3).
Configuration and Interface Dimensions of WNS Series Pressure Hot Water Boilers
Item | type | WNS0.35 | WNS0.7 | WNS1.4 | WNS2.8 | WNS4.2 | WNS7 | WNS105 | WNS14 | |
Host transport dimensions (length * width * height) | / | mm | 2949*14 54*1707 | 3198*18 80*2166 | 4131*22 47*2422 | 4928*22 50*2600 | 5401*24 06*2650 | 6280*26 40*3176 | 7804*33 93*3540 | 9120*44 00*4100 |
Host Weight | / | t | 2.8 | 5 | 8 | 10.5 | 17.8 | 19 | 35 | 48 |
Outlet Valve Diameter | DN | mm | 50 | 65 | 100 | 125 | 125 | 200 | 200 | 200 |
Backwater Valve Diameter | DN | mm | 50 | 65 | 100 | 125 | 125 | 200 | 200 | 200 |
Atmospheric Connecting Pipe Diameter | DN | mm | 40 | 50 | 2,40 | 2*50 | 2,65 | 2,80 | 2*100 | 2*150 |
Drainage Valve Diameter | DN | mm | 40 | 40 | 2*40 | 2*40 | 2,40 | 2*40 | 2*50 | 2*50 |
Chimney diameter | DN | mm | 250 | 280 | 350 | 400 | 600 | 750 | 1000 | 1100 |
Note: Due to the continuous updating of products, the company reserves the right to modify the data in the above two tables.