Product Discription
LSS Oil Fired Steam Generator
The vertical structure provided by the LSS recognizes vertical rock structures. A special protective tube between the two lower arrows and the upper and lower protective tubes generates three gases. Zoom in and shoot
The heating characteristic of hot seeds and heat capacitor varies from 93% to 100%. Use a domestic water bottle and an outdoor shower. Water stone delivers high quality dry burn, reduces system size and extends battery life.
1. Easy to use:
Underneath the inspection door is a door to inspect and clean for easy maintenance of the interior and interior of the wash.
2. It is necessary to meet the following environmental requirements:
Functional and reliable combustion burns all the burns but makes it difficult to remove the dangerous bombardment. Test results from a variety of different types indicate that gas meets the requirements of the environment.
3. Irrigation fees can be increased:
The air motor is designed (without limitation) by most units and can be controlled by a computer. You can add shared tasks. The plant produces a lot of air pollution (water purification, pumps, burners, electronic control panels and main vacuum blocks).
4. Installation is complete:
Water, electricity and air can be connected to the site, saving time and installation work.
5. Reliable tools:
Vodka, check paper, water purifier and vacuum cleaner, support national pump quality equipment. The support system provides a safe and reliable climate to achieve and improve air quality.
Technical Parameters
Main Technical Reference for Fuel (Gas) Steam Generator | ||||||
Item Unit | LSS0.05 | LSS0.1 | LSS0.15 | LSS0J2 | ||
Rated evaporation | Kg/h | 50 | 100 | 150 | 200 | |
Rated Pressure PTEPREppoPressure | MPa | 0.4/0.7 | ||||
Rated steam temperature | c | 151/171 | ||||
Rated feed water temperature | °C | 20 | ||||
Evaporator efficiency | / | >92% | ||||
Applicable Fuel | / | Gas light oil | ||||
Theoretical fuel consumption | Gas | NM3/h | 4 | 8 | 12 | 16 |
Light Oil | Kg/h | 3.3 | 6.5 | 9.8 | 13 | |
Gas supply pressure | mbar | 60- 100 | ||||
water volume | L | <30 |
Note: The fuel consumption in the table is based on the low calorific value of biomass particles 17084 KJ/Kg (4085 Kcal/Kg).Calculations show that if the low calorific value of biomass fuel is higher than that, the corresponding fuel consumption will be more economical than the values in the table.
Configuration and Interface Size of Fuel (Gas) Steam Generator | ||||||
Item Unit | LSS0.05 | LSSO.l | LSS0.15 | LSS0.2 | ||
Outward Size of Main Engine
(length * width * height) | / | mm | 620*620*830 | 690*690*968 | 750*750*1130 | 800*800*1286 |
Transport Dimension
| / | mm | 206 | 252 | 303 | 350 |
Mainframe Transport Weight | DN | mm | G 1/2- | Gl' | Gl" | G 1* |
Main Steam Valve Pipe Diameter | DN | mm | Gl/2" | Gl/2- | Gl/2- | Gl/2° |
Feed Water Valve | DN | mm | G1 1/4” | G11/4- | G11/4- | G11/4- |
Safety Valve Diameter | DN | mm | Gf | GF | Gl" | Gl" |
Drain Valve Pipe Diameter | DN | mm | 133 | 133 | 159 | 159 |
Remarks: We will reserve rights to change the above mentioned data due to continuous policy transformation and product improvement.