Product Discription
LSS oil and gas fired vertical steam generator
The vertical gas vapour generator LSS adopts a vertical pipe structure. There are two rings of pipe bundles and a tube with a cap welded with between the upper and lower tube sheets of the main body to form a three -cycle flow gas. The gas has a long warm transfer process The burner is placed on the top of the body, and the flame can be fully expanded and Hey.
With boiler and condenser, the thermal output can reach 93%-100%.The integrated steam -water separator and the external steam separator provide dry steam. high quality, fuel savings, reduction of system escalation and extension of service life.
1. In accordance with environmental requirements:
High quality and reliable fuel can cause the fuel to burn completely and significantly reduce harmful gas emissions. The results the tests of the relevant sections show that the fuel (gas) producer complies with national environmental protection requirements.
2. Evaporation may be increased:
Steam production can be configured in many units (unlimited number) and controlled by the computer. Total exhaust can be freely increased.
3. The facility is complete:
The space can be connected to water, electricity and steam pipes to save installation time and energy.
4. Reliable components:
Support burners, control boxes, water treatment, valves, pumps and other high -quality household equipment. The auxiliary equipment may be: ensure the safe and reliable operation of the steam generator and improve the overall quality of the steam generator.
5. Exceptional control system:
The boiler has a perfect automatic control device and safety device for the application of an automatic water level control system; and alarm and interruption of the water level; automatic steam pressure control system and excess pressure alarm; automatic boiler ignition Dynamic control of the automatic combustion of the burner and protection of extinction to ensure safe operation of the boiler. The user only needs Press the start button slightly, and the steam generator can push it.
6. Good service:
Technical consultation, technical services, installation guidance, regular and informal visits to users, at all times to provide quality waste services, so that users can be quiet and buy
Technical Parameters
Main Technical Reference for Fuel (Gas) Steam Generator
Item Unit | LSS0.05 | LSS0.1 | LSS0.15 | LSS0J2 | ||
Rated evaporation | Kg/h | 50 | 100 | 150 | 200 | |
Rated Pressure PTEPREppoPressure | MPa | 0.4/0.7 | ||||
Rated steam temperature | c | 151/171 | ||||
Rated feed water temperature | °C | 20 | ||||
Evaporator efficiency | / | >92% | ||||
Applicable Fuel | / | Gas light oil | ||||
Theoretical fuel consumption | Gas | NM3/h | 4 | 8 | 12 | 16 |
Light Oil | Kg/h | 3.3 | 6.5 | 9.8 | 13 | |
Gas supply pressure | mbar | 60- 100 | ||||
water volume | L | <30 |
Note: The fuel consumption in the table is based on the low calorific value of biomass particles 17084 KJ/Kg (4085 Kcal/Kg).Calculations show that if the low calorific value of biomass fuel is higher than that, the corresponding fuel consumption will be more economical than the values in the table.
Configuration and Interface Size of Fuel (Gas) Steam Generator
Item Unit | LSS0.05 | LSSO.l | LSS0.15 | LSS0.2 | ||
Outward Size of Main Engine
(length * width * height) | / | mm | 620*620*830 | 690*690*968 | 750*750*1130 | 800*800*1286 |
Transport Dimension
| / | t | 206 | 252 | 303 | 350 |
Mainframe Transport Weight | DN | mm | G 1/2- | Gl' | Gl" | G 1* |
Main Steam Valve Pipe Diameter | DN | mm | Gl/2" | Gl/2- | Gl/2- | Gl/2° |
Feed Water Valve | DN | mm | G1 1/4” | G11/4- | G11/4- | G11/4- |
Safety Valve Diameter | DN | mm | Gf | GF | Gl" | Gl" |
Drain Valve Pipe Diameter | DN | mm | 133 | 133 | 159 | 159 |
Remarks: We will reserve rights to change the above mentioned data due to continuous policy transformation and product improvement.