Product Discription
LSS oil and gas fired vertical steam generator
LSS fuel gas vertical steam generator takes on vertical tubular structure. There are two rings of tube connection and a casing welded between the upper and lower tube blades of the main body to form a three -cycle flue gas. The flue gas has a long heat transfer, a large heating The burner is on the top of the body, and the flame can fully expand and burn.
With the help of a boiler and condenser, the thermal efficiency 93% 100%.Built -in steam separator and external steam separator can ensure a high quality of dry steam, save fuel, reduce the scale increase of the system and extend the service life.
1. In accordance with environmental requirements:
The high quality and reliable combustion can cause the fuel to burn fully and significantly reduce the harmful emission of flue gas. The test results from the relevant sections show that the steam generator for fuel (gas) meets national environmental protection requirements.
2. Evaporation may be increased:
Steam generators can be modulated in many units (unlimited number) and controlled by computers. Total evaporation can be freely increased. Relevant components of the steam generator (including water treatment, water pump, burners, electronic control box and main valve instrument) are already in the factory.
3. Installation is a whole:
The installation may be connected to water, electricity and steam pipes to save installation time and energy.
4.Reliable accessories:
Combustion burners, control boxes, water treatment, valves, pumps and other high -quality household appliances; the support equipment can ensure the safe and reliable operation of the steam generator and improve the overall quality of the steam generator.
5. Excellent control system:
Boilers have a perfectly automatic control and a safety -responsive device to implement an automatic water stop system and a low water level alarm and shut -down; automatic control of vapour pressure and over -pressure alarm; automatic ignition of the boiler, dynamic adjustment of the burner spontaneous combustion and extinguishing protection to ensure safe operation of the boiler. The user only needs to press the start button lightly and the steam generator can press it.
6. Good service:
Technical consultation, technical services, installation instructions, regular and irregular visits to users at any time to provide quality and perfect service for users to be safe and to buy
Technical Parameters
Main Technical Reference for Fuel (Gas) Steam Generator
Item Unit | LSS0.05 | LSS0.1 | LSS0.15 | LSS0J2 | ||
Rated evaporation | Kg/h | 50 | 100 | 150 | 200 | |
Rated Pressure PTEPREppoPressure | MPa | 0.4/0.7 | ||||
Rated steam temperature | c | 151/171 | ||||
Rated feed water temperature | °C | 20 | ||||
Evaporator efficiency | / | >92% | ||||
Applicable Fuel | / | Gas light oil | ||||
Theoretical fuel consumption | Gas | NM3/h | 4 | 8 | 12 | 16 |
Light Oil | Kg/h | 3.3 | 6.5 | 9.8 | 13 | |
Gas supply pressure | mbar | 60- 100 | ||||
water volume | L | <30 |
Note: The fuel consumption in the table is based on the low calorific value of biomass particles 17084 KJ/Kg (4085 Kcal/Kg).Calculations show that if the low calorific value of biomass fuel is higher than that, the corresponding fuel consumption will be more economical than the values in the table.
Configuration and Interface Size of Fuel (Gas) Steam Generator
Item Unit | LSS0.05 | LSSO.l | LSS0.15 | LSS0.2 | ||
Outward Size of Main Engine
(length * width * height) | / | mm | 620*620*830 | 690*690*968 | 750*750*1130 | 800*800*1286 |
Transport Dimension
| / | t | 206 | 252 | 303 | 350 |
Mainframe Transport Weight | DN | mm | G 1/2- | Gl' | Gl" | G 1* |
Main Steam Valve Pipe Diameter | DN | mm | Gl/2" | Gl/2- | Gl/2- | Gl/2° |
Feed Water Valve | DN | mm | G1 1/4” | G11/4- | G11/4- | G11/4- |
Safety Valve Diameter | DN | mm | Gf | GF | Gl" | Gl" |
Drain Valve Pipe Diameter | DN | mm | 133 | 133 | 159 | 159 |
Remarks: We will reserve rights to change the above mentioned data due to continuous policy transformation and product improvement.