LSS oil and gas fired vertical steam generator
A vertical steam generator for LSS gas uses a vertical tube structure.There are two rings of tube bottoms and a cartridge tube welded between the head and the lower tube of the main body, which forms a smoke gas with three cycles.The smoke gas has a long heat transfer, a large heat area and a former The burner is placed on top of the body, and the flame can expand and burn.
With a boiler and condenser, thermal efficiency can reach 93%100%.Built -in steam water separator and external steam water separator provides high quality dry steam, saves fuel, reduces system scaling and prolongs service life.
1. Reasonable design:
The main body of the steam generator adopts a vertical tubular structure. The upper and lower Tubesheets of the Main Body are Soldiers with two coils of Water Pipe Packets, forming a triple melt of combustion gas with the barrel of shell. The TEM Long Transfer Process of Heat, Large Area of Heat and Discharge The burner is placed in the Body TOPO, and the Flame can expand completely and burn.
2. High efficiency and energy savings:
The thermal efficiency of the steam generator can reach over 92%, and the steam generator with condenser can achieve more than 96%.
3. Production specifications:
Steam generating components are manufactured in accordance with national and international standards (ISO). Strict production processes are rigorously followed on all production links to ensure the reliable quality of the Product.
4. Steam drying:
Steam generator with built -in steam water separator can provide high quality dry steam. Because it is cooked. Steam helps eliminate unnecessary extra condensation, thereby saving fuel, reducing system scale and extending service life.
5. Reliable and durable:
Excellent professional steam generator project, excellent production technology, rigorous quality control, is the quality assurance of cadA steam generator.
Technical Parameters
Main Technical Reference for Fuel (Gas) Steam Generator
Item Unit | LSS0.05 | LSS0.1 | LSS0.15 | LSS0J2 | ||
Rated evaporation | Kg/h | 50 | 100 | 150 | 200 | |
Rated Pressure PTEPREppoPressure | MPa | 0.4/0.7 | ||||
Rated steam temperature | c | 151/171 | ||||
Rated feed water temperature | °C | 20 | ||||
Evaporator efficiency | / | >92% | ||||
Applicable Fuel | / | Gas light oil | ||||
Theoretical fuel consumption | Gas | NM3/h | 4 | 8 | 12 | 16 |
Light Oil | Kg/h | 3.3 | 6.5 | 9.8 | 13 | |
Gas supply pressure | mbar | 60- 100 | ||||
water volume | L | <30 |
Note: The fuel consumption in the table is based on the low calorific value of biomass particles 17084 KJ/Kg (4085 Kcal/Kg).Calculations show that if the low calorific value of biomass fuel is higher than that, the corresponding fuel consumption will be more economical than the values in the table.
Configuration and Interface Size of Fuel (Gas) Steam Generator
Item Unit | LSS0.05 | LSSO.l | LSS0.15 | LSS0.2 | ||
Outward Size of Main Engine
(length * width * height) | / | mm | 620*620*830 | 690*690*968 | 750*750*1130 | 800*800*1286 |
Transport Dimension
| / | t | 206 | 252 | 303 | 350 |
Mainframe Transport Weight | DN | mm | G 1/2- | Gl' | Gl" | G 1* |
Main Steam Valve Pipe Diameter | DN | mm | Gl/2" | Gl/2- | Gl/2- | Gl/2° |
Feed Water Valve | DN | mm | G1 1/4” | G11/4- | G11/4- | G11/4- |
Safety Valve Diameter | DN | mm | Gf | GF | Gl" | Gl" |
Drain Valve Pipe Diameter | DN | mm | 133 | 133 | 159 | 159 |
Remarks: We will reserve rights to change the above mentioned data due to continuous policy transformation and product improvement.