Product Discription
LSS Oil Fired Steam Generator
LSS oil and gas -fired vertical steam generators use vertical pipe structure.There are two circles of tube bottoms and a cartridge cylinder welded between the upper and lower tubes of the body, forming a three -return flue gas.It has a long flue -gas heat transfer, sufficient heat area and a reasonable structure. The burner is placed on top of the body and the flame can be fully expanded and burned.
It uses a boiler and condenser and its thermal efficiency can reach 93%100%.It has a steam -water separator and external steam -water separator that can deliver high quality dry steam, saving fuel, reducing system scaling and extending service life.
1. Reasonable design:
The steam generator body adopts a vertical ornamental structure, connecting the upper and lower pipes of the body with two pipes welded by two pipes, and performing three times. The performance process is long, the heating area is large, and the configuration of the structure is reasonable. Enemy. The burner is mounted at the top of the body, and the flame is enough to expand and burn.
2. Efficient and economical:
the steam heating rate is over 92%, and the steam engine efficiency should be 96%.
3. Manufacturing Specification:
All parts of steam generator are manufactured in strict accordance with national and international standards (ISO), and the production process strictly complies with the product quality.
4. Four Steam drying:
visceral steam separator of steam generator, high quality dry steam. Steam helps eliminate unnecessary additional condensation, save fuel, reduce system condensation and prolong service life.
5. reliable:
excellent steam generator specially designed, excellent production technology, strict quality control, quality assurance of each steam generator.
Technical Parameters
Main Technical Reference for Fuel (Gas) Steam Generator | ||||||
Item Unit | LSS0.05 | LSS0.1 | LSS0.15 | LSS0J2 | ||
Rated evaporation | Kg/h | 50 | 100 | 150 | 200 | |
Rated Pressure PTEPREppoPressure | MPa | 0.4/0.7 | ||||
Rated steam temperature | c | 151/171 | ||||
Rated feed water temperature | °C | 20 | ||||
Evaporator efficiency | / | >92% | ||||
Applicable Fuel | / | Gas light oil | ||||
Theoretical fuel consumption | Gas | NM3/h | 4 | 8 | 12 | 16 |
Light Oil | Kg/h | 3.3 | 6.5 | 9.8 | 13 | |
Gas supply pressure | mbar | 60- 100 | ||||
water volume | L | <30 |
Note: The fuel consumption in the table is based on the low calorific value of biomass particles 17084 KJ/Kg (4085 Kcal/Kg).Calculations show that if the low calorific value of biomass fuel is higher than that, the corresponding fuel consumption will be more economical than the values in the table.
Configuration and Interface Size of Fuel (Gas) Steam Generator | ||||||
Item Unit | LSS0.05 | LSSO.l | LSS0.15 | LSS0.2 | ||
Outward Size of Main Engine
(length * width * height) | / | mm | 620*620*830 | 690*690*968 | 750*750*1130 | 800*800*1286 |
Transport Dimension
| / | mm | 206 | 252 | 303 | 350 |
Mainframe Transport Weight | DN | mm | G 1/2- | Gl' | Gl" | G 1* |
Main Steam Valve Pipe Diameter | DN | mm | Gl/2" | Gl/2- | Gl/2- | Gl/2° |
Feed Water Valve | DN | mm | G1 1/4” | G11/4- | G11/4- | G11/4- |
Safety Valve Diameter | DN | mm | Gf | GF | Gl" | Gl" |
Drain Valve Pipe Diameter | DN | mm | 133 | 133 | 159 | 159 |
Remarks: We will reserve rights to change the above mentioned data due to continuous policy transformation and product improvement.