Product Discription
SZS Pressure Hot Water Boiler
The SZS series are double -drum steam boilers, with gas vapour, with two drums, of the type longitudinal, water -piped boilers that charge quickly. The series of boilers consists of upper and lower drums, membrane walls, convection tubes and capacitors. Fuel burns in the boiler. The gas is discharged into the basket from the convection tubes and the waste heat recovery device. With the Mechatronics structure, performance is at the level of leadership in China.
Product Features
1. Advanced control system:
Fully automatic control, users only have to press the start button, the boiler can be configured according to the program to start operation. Load control and automatic water supply are all automatic operations to meet the requirements u user.
2. In accordance with environmental requirements:
The furnace area is large, and is equipped with high quality and reliable imported burners, so that the fuel can be completely burned, and the harmful components in the combustion gases are reduced to a large extent. The inspection by the relevant departments shows that oil -fired gas boilers meet the strictest national environmental protection requirements and meet national environmental protection requirements.
3. Miscellaneous fuels applicable:
The furnace surface is large, fuel combustion is sufficient, especially for low calorific fuels such as coke oven gas, furnace gas etc. The efficiency of high calorific fuel combustion is better, such as natural gas I, liquefied gas etc.
4. Reasonable structure:
It is easy to attach the burner head by installing the water wall in front of the boiler, which ensures the water level and cooling near the burner, and helps to remove the carbon stock in the burner and make the fuel burn more fully.
5. Easy to maintain:
The blast -resistant doors, the fire -resistant orifice and the revision door are fixed to the boiler wall and the channel door is set on the front and back of the barrel to facilitate the boiler review.
Technical Parameters
Main technical parameters of SZS series pressure cushion water boilers | ||||||||||
Item Type | SZS7 | SZS10.5 | SZS14 | SZS21 | SZS29 | SZS35 | SZS42 | SZS46 | ||
Rated Heat Efficiency | MW | 7 | 105 | 14 | 21 | 29 | 35 | 42 | 46 | |
Rated Working Pressure | MPa | 1.0/125 | L0/L25 | 1.0/1^5 | 1^5/1.6 | 125/L6 | 1-25/1.6 | L25/L6 | 1.25/16 | |
Rated Effluent temperature | °C | 115/130 | 115/130 | 115/130 | 115/130 | 115/130 | 115/130 | 115/130 | 115/130 | |
Return water temperature | °C | 70 | 70 | 70 | 70 | 70 | 70 | 70 | 70 | |
Efficiency | / | >96% | ||||||||
Design Fuel | / | Natural gas, liquid gas, city gas, light oil
Liquefied gas,
City Gas
Light oil | ||||||||
Fuel Theoretical consumption | gas | NM3/h | 731 | 1097 | 1462 | 2191 | 3026 | 3657 | 4383 | 4799 |
Liquid gas | Kg/h | 586 | 877 | 1169 | 1755 | 2421 | 2928 | 3511 | 3843 | |
City Gas | NM3/h | 1572 | 2354 | 3138 | 4705 | 6503 | 7839 | 9149 | 9991 | |
Light Oil | Kg/h | 599 | 899 | H93 | 1801 | 2479 | 2989 | 3601 | 3943 | |
Natural gas | mbar | 150-200 | 150-300 | 150-300 | 150-300 | 150-300 | 150-300 | 150-300 | 150-300 | |
City gas | mbar | 150-200 | 150-300 | 150-300 | 150-300 | 150-300 | 150-300 | 150-300 | 150-300 | |
Rated water circulation | M³/h | 133/100 | 200/150 | 266/200 | 400/300 | 551/414 | 665/500 | 798/600 | 874/657 |
Note: The fuel consumption in the table is calculated by low calorific value of light oil 42915KJ/Kg (10260Kcal/Kg), low calorific value of natural gas 35588KJ/NM3 (8500Kcal/NM3), low calorific value of liquefied gas 45998KJ/Kg (11000Kcal/Kg), low calorific value of urban gas 16750K/NM3 (4000Kcal/NM3).
Configuration and Interface Dimensions of SZS Series Pressure Overlay Boilers | ||||||||||
Item | type | SZS7 | SZS10.5 | SZS14 | SZS21 | S2S29 | SZS35 | SZS42 | SZS46 | |
Host transport dimensions (length * width * height) | / | mm | 5633*33 00*3400 | 6365*35 85*3478 | 8781*36 25.383 | Separate transportation | Separate transportation | Separate transportation | Separate transportation | Separate transportation |
Host Weight | / | t | 150/200 | 200 | 200 | 300 | 300 | 350 | 350 | 400 |
Outlet Valve Diameter | DN | mm | 150/200 | 200 | 200 | 2*200 | 2*200 | 2*200 | 2*200 | 2*300 |
Backwater Valve Diameter | DN | mm | 50 | 50 | 2*50 | 2*50 | 2*50 | 2*50 | 2*50 | 2*50 |
Atmospheric Connecting Pipe Diameter | DN | mm | 750 | 1000 | 1100 | 1400 | 1700 | 2000 | 2000 | 2200 |
Note: Due to the continuous updating of products, the company reserves the right to modify the data in the above two tables.