Product Discription
WNS Condensing Steam Boiler
The product model is WNS. It is an internal horizontal combustion of three -way fuel (gas) of fast charging Caldeira integrated with wet rear structure. The Onda tank and the ignition chamber are the first time, the second time is the combustion gas tube, and the third time is composed of econom Laser and capacitor.
This Product is used to burn light oil, natural gas and so on. The fuel is ejected from the burner, ignited by an electronic ignition rod, and burned under a slightly positive pressure in the oven. High temperature smoke after burning enters the threaded smoke pipe through the 180 -degree reflux chamber, and enters the smoke box from the front through the smoke tube.
Product Features
1. Appropriate design:
Horizontal internal combustion with three cycles full of wet tail structure, 100% fire water construction, 100% wave furnace bubble, has good extensibility, sufficient heat range and a reasonable structure.
2. High efficiency and energy saving:
The structure of the blast furnace, the thread tube and the large combustion chamber is adequate, the energy consumption is low and the heat transfer performance high. The thermal efficiency of boilers may exceed 96% and if capacitors are installed, the efficiency may be 100%.
3. Technical data:
The boiler components are manufactured according to national and international standards (ISO). Advanced production technologies are closely monitored at every stage of production to ensure product quality.
4. Large steam chamber:
As steam drying helps to avoid unnecessary additional condensation, reduce fuel consumption, reduce and prolong service life, coke has sufficient steam bath to cope with load fluctuations and peak values and steam for a high quality e Provide drying.
5. Duration and durability:
Excellent professional design, advanced production technology and strict quality control ensure the quality of all boilers in the regions of Henan and Hebei.
6. Easy maintenance:
At the front and back there is a portable smoke door and at the back a control hole for the control and cleaning of the furnace. There are maintenance holes, mechanical holes and manual holes in the body, and the latter is fully taken into account in the construction.
Technical Parameters
Main Technical parameters of WNS Condensing Steam Boiler | |||||||||
Item | Unit | WNS1 | WNS2 | WNS4 | WNS6 | WNS8 | WNS10 | WNS15 | |
Steam Capacity | t/h | 1 | 2 | 4 | 6 | 8 | 10 | 15 | |
Working Pressure | MPa | 1.0 | 1.25 | 1.25 | 1.25 | 1.25 | 1.25 | 1.25 | |
Steam Temperature | ℃ | 184 | 193 | 193 | 193 | 193 | 193 | 193 | |
Feed Water Temperature | ℃ | 20 | 20 | 20 | 20 | 20 | 20 | 20 | |
Thermal Efficiency | / | ≥100% | |||||||
Fuel | / | Natural gas, liquefied gas, city gas, light oil | |||||||
Fuel Consumption | Natural gas | NM3/h | 67 | 135 | 273 | 408 | 547 | 681 | 1019 |
Liquefied gas | Kg/h | 54 | 109 | 217 | 328 | 438 | 547 | 823 | |
City gas | NM3/h | 145 | 293 | 585 | 880 | 1162 | 1466 | 2202 | |
Light oil | Kg/h | 58 | 116 | 230 | 341 | 470 | 573 | 872 | |
Gas Feed pressure | Natural Gas | mbar | 100-150 | 100-150 | 150-200 | 150-200 | 150-200 | 150-200 | 150-300 |
City Gas | mbar | 100-200 | 100-200 | 150-200 | 150-200 | 150-200 | 150-200 | 150-300 | |
Running water volume | M3 | 3.2 | 3.5 | 6 | 9 | 10.94 | 12.17 | 21.76 |
Note: the fuel consumption in the table is based on light oil low calorific value 42915KJ/Kg (10260Kcal/Kg), natural gas low calorific value 35588KJ/NM3 (8500Kcal/NM3) and liquefied gas low calorific value 45998KJ/Kg (11000Kcal/Kg). Calculation of low calorific value (16750KJ/NM3 (4000Kcal/NM3) of urban gas.
Shape and Interface Dimensions of WNS Condensing Steam Boiler | |||||||
Item | Unit | WNS6 | WNS8 | WNS10 | WNS15 | ||
Transport Dimension (L*W*H) | / | mm | 5132*2807*3958 | 6052*3146*4083 | 6096*3205*4525 | 7804*3465*3540 | |
Mainframe transport weight | / | t | 16 | 21 | 25 | 46 | |
Main Steam Valve Pipe Diameter | DN | mm | 125 | 125 | 150 | 200 | |
Feed Water Valve | DN | mm | 50 | 50 | 50 | 65 | |
Safety Valve Diameter | DN | mm | 2*80 | 2*80 | 2*80 | 2*100 | |
Drain Valve Pipe Diameter | DN | mm | 2*40 | 2*40 | 2*40 | 2*50 | |
Chimney Diameter | φ | mm | 600 | 600 | 750 | 1000 |
Remarks: We will reserve rights to change the above mentioned data due to continuous policy transformation and product improvement.