Specifications
Brand Name :
BIOVANTION
Place of Origin :
China
MOQ :
50kits
Assay Time :
2 Hours
Assay Type :
Immunological Assay
Detection Limit :
Low
Expiration Date :
18 months
Organism :
Homo sapiens (Human)
Product Type :
Research Test Kit
Reactivity :
Highly reactive
Sample Type :
Biological Samples
Sample Volume :
50 µL
Specificity :
High Specificity
Test Sample Type :
Serum, Plasma
Test Species :
Human
Time To Results :
Rapid Results
Description

Research test for the quantitative determination of SAA Kit in human serum on automate chemistry analyzers

RUO Serum Amyloid A (SAA) Assay(Latex Immunoturbidimetric)

SAA (Serum Amyloid A) is is an acute-phase protein. During
inflammation, infectious and non-infectious diseases, its concentration in the blood can rise sharply within a few hours, and can rise to 1000 times the initial concentration. SAA is
related to HDL, and it can It regulates the metabolism of HDL
during inflammation. A particularly important feature of SAA is
that its degradation products can be deposited in different organs
in the form of amyloid A fibrils. This is a serious complication in
chronic inflammatory diseases; Elevated serum amyloid A is also
seen in atherosclerosis, diabetic nephropathy, acute myocardial
infarction, coronary heart disease, and chronic kidney disease

Components

Contents components Concentration

R1

PBS Buffer NaCl Surfactant

Antiseptic

0.1 mol/L Titer Titer

Titer

R2

Latex particles coated with SAA antibody

PB Buffer NaCl Surfactant

Antiseptic

>0.5mg/L

0.1 mol/L Titer Titer

Titer

Calibrator

/Control

SAA

Bovine serum albumin NaCl

Surfactant

Antiseptic

See Value Sheet Titer

Titer Titer

Titer

RUO Serum Amyloid A (SAA) Assay(Latex Immunoturbidimetric)

【Procedure】

Reagent preparation:

R1: Ready for use; R2: Ready for use. Wavelength:570nm Temperature:37℃

Direction: Increase

Blank Tube Calibration Tube Sample Tube
Sample 2ul
Calibrator 2ul
Deionized water 2ul
R1 200μl 200μl 200μl
Mix, incubate at 37℃ for 5 minutes.
R2 40μl 40μl 40μl

Mix, incubate at 37℃ for 5 minutes, zero setting for blank

tube, read the absorbance A calibrator and A sample

Calibration

It is recommended to use the SAA Calibrators for calibration. Dissolve the lyophilized SAA calibrator with 1ml distilled water, and dilute to 6 calibrators as follows,

Dilute 1 2 3 4 5 6
CAL (μl) 200 100 50 50 25 0

Normal

Saline (μl)

0 100 150 350 375 200
ratio 1 1/2 1/4 1/8 1/16 0

Calibration Method:Spline or other non-linear method

Quality control

It is recommended to use the SAA Quality Control level 1 and level 2 for daily quality control.

Two levels of controls should be assayed at least once a day. Values obtained should fall within a specified range.

Each laboratory should establish its own internal Quality Control scheme and procedures for corrective action if controls do not recover within the acceptable tolerances.

Calculation:

The analyzer automatically calculate the analyte concentration of each sample.

Send your message to this supplier
Send Now

RUO Serum Amyloid A (SAA) Assay(Latex Immunoturbidimetric)

Ask Latest Price
Brand Name :
BIOVANTION
Place of Origin :
China
MOQ :
50kits
Assay Time :
2 Hours
Assay Type :
Immunological Assay
Detection Limit :
Low
Contact Supplier
RUO Serum Amyloid A (SAA) Assay(Latex Immunoturbidimetric)

Biovantion Inc.

Verified Supplier
4 Years
beijing, beijing
Business Type :
Manufacturer, Importer, Exporter, Trading Company, Seller
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement