K-G60-S4 Fixed Gas Detector
Introduction
Multi 4in1 fixed gas detector, can detect EX,O2,CO,H2S (support other gas combinations),have ATEX, CE, FCC, ROHS, SIL certification.
Specification
Gas type | EX | O2 | CO | H2S |
Range | 0-100%LEL | 0-30%vol | 0-1000ppm | 0-100ppm |
Resolution | 1%LEL | 0.1%vol | 1PPM | 1PPM |
Sensor type | support electri-chemical, Catalytic ,semi-conductor, PID, infrared sensors |
|||
Detection method | diffusion, pump |
|||
Installation | wall mounted, pipe line (Thread size: G1/2) | |||
Working voltage | DC(24+-3.6)V power: 1.6W | |||
Response time | ≦30s (T90) |
|||
Deviation | ±3%FS | |||
Repetition | ≦2% | |||
Relay | two relay output, free contact: 30VDC 1A/125VAC 0.3A |
|||
Degree of protection | IP65 | |||
Explosion-Proof | Ex d II T6 GB |
|||
Shell material | Die-casting aluminumExplosion-proof and anti-corrosion | |||
Thread size | M20X1.5 , G1/2 |
|||
Dimension | 261*177*90mm cable: >4x1.5mm2 shielded cable | |||
Working temperature | -10℃-50℃ | |||
Working humidity | ≦95% RH, no condensation |
|||
Working pressure | 86-106Kpa |
Details