Computer Monitoring Voltage And Current Converter Aging Test Equipment
Burn-in cabinet structure and Burn-in quantity planning | Trolley size (mm) | L2050*W1250*H2050mm (size of a single Burn-in cabinet) |
Number of trolley layers | 6 layers, product area depth 400mm, (6 Burn-in positions per layer) | |
Trolley height | 175mm | |
Trolley structure material | 2.0mm thick cold rolled sheet | |
Load area cooling method | Top turbine exhaust fan top row type (easy to control the ambient temperature) | |
Layer insulation and anti-static method | Epoxy insulation board with heat dissipation holes on the surface | |
Overall burn-in room structure | Adopt mobile Burn-in split cabinet; beautiful appearance and easy to move and combine | |
Introduction to energy recovery module configuration, power of the tested power supply and Burn-in quant | Energy recovery module control method | RS485 communication mode, upper computer uses RS232 communication mode |
Product burn-in mode | The burn-in process of the product is carried out by the way of relative drag | |
Dc power isolation mode | Dc power channel adopts photoelectric isolation (communication and power supply isolation) | |
Energy recovery module design architecture | No relay, long life design scheme (independent intellectual property rights) | |
Introduction of electric control and temperature control device for power Burn-in cabine | Wiring | Customer specified interface; Input/output port Anderson connector |
Panel function keys | Input AC voltage display, start switch, emergency stop switch | |
Trolley power distribution and control mode | 380V three-phase five-wire distribution; Computer monitoring and automatic electric control | |
Trolley power distribution | A single burn-in cabinet is 3000W*36/0.85≈127KW, and the measured power efficiency is calculated as 85% | |
Way to control | The electric control includes manual/automatic switching, which is monitored by the computer in real time when burn-in. The electric control cabinet can extend the automatic switching function of AC voltage | |
Safety protection | Equipment grounding protection, leakage switch protection, smoke alarm automatic power-off protection, etc. | |
Introduction to the main functions of the system | Applicable to energy storage power,current converter, inverter, regurgitator,transverter, medical power supply and so on | |
Free configuration of self-developed special monitoring software for power Burn-in, with independent intellectual property rights and no legal risks | ||
Use programmable electronic load module to monitor output terminal voltage, current and power parameters | ||
Dedicated monitoring software for Burn-in enjoys free final upgrade service, powerful expansion function, saving repeated investment in equipment |