System | System structure | 1 control cabinet + 2 burn-in cabinets |
Overall size | 5100*1200*2050mm | |
Total floor area | 5100*2200mm(Including operation area) | |
Total input voltage | Three-phase five-wire system 220Vac (rated) | |
Total input current | 100A | |
Total input power | 50kW | |
Application ambient temperature | 0-40℃ | |
Application environment humidity | 0-95% | |
Fire protection requirements | Materials meet UL 94V0 rating | |
Environmental requirements | Materials comply with Rohs, WEEE requirements | |
Safety requirements | Comply with IEC62368 international standard design requirements | |
Burn-in cabinet | Burn-in bits/cabinet | 16 bits/cabinet |
Burn-in bits/layer | 4 bits/layer | |
Burn-in product power | 7kW/bit | |
Burn-in product input voltage | 50-750Vdc/bit | |
Burn-in product input current | 25A/bit | |
Burn-in Product Load Category | 6.6kW/bit | |
Burn-in product load current | 220Vac/50Hz | |
Burn-in product output current | 32A/bit | |
AC Connector Type | PA45 (L/N/PE) | |
DC Connector Type | MC4 photovoltaic connector (PV+/PV-/4 groups) | |
Signal Connector Type | RJ45 (network port) | |
Bit Status Indicator | No | |
Input power | 130kW | |
Feedback power | 105.6kW | |
Constant temperature range | Room temperature+5°C-60°C | |
Constant temperature accuracy | ±5°C | |
Number of temperature control points | 5 | |
Open type | Sliding door/folding door/side door | |
Volume size | 2100*1200*2050mm | |
Dimensions in the product area | 1700*550*1500mm | |
Product area layers | 4 | |
Bit space size | 425*550*350mm | |
Minimum floor height | 300mm | |
Top floor height | 1450mm | |
Product area air duct direction | Left and right ventilation | |
Cooling method | Air cooling | |
Material | 1.5mm cold rolled sheet, epoxy sheet (laminate) | |
Monitoring software | Display running information | Input voltage, current, power, output voltage (DC source module communication or product communication) |
Show status information | Not Connected / Vacant / Passed / Under Voltage / Under Current / Over Voltage / Over Current / No Output / Protection | |
Display accuracy | ±(1%+0.2%FS) | |
Control precision | ±(1%+0.2%FS) | |
Bad way of reporting | Audible alarm | |
Report format | CSV format | |
Statistics | Yield/CPK/Time Distribution | |
MES docking | Support | |
Scan speed | 5S | |
Control cabinet | Control system | Window 10 |
Display medium | Computers and Monitors | |
Manipulating medium | Mouse and keyboard | |
Communication method | Cable | |
Type of protection | Over current, leakage, over temperature, smoke, emergency stop | |
Alarm method | Sound and light alarm, remote network | |
Heat dissipation type | Air cooling | |
Maintenance mode | Post maintenance | |
Material | 1.5mm cold rolled sheet | |
Volume size | 880*860*1900mm |