Burn-In Test Facility For Small String Inverters Converter Reflux Transformer
Architecture diagram


Performance parameters

System | System structure | 1 control cabinet + 2 burn-in cabinets |
Overall size | 5100*1500*2050mm |
Total floor area | 5100*2500mm(Including operation area) |
Total input voltage | Three-phase five-wire system 220Vac (rated) |
Total input current | 300A |
Total input power | 160kW |
Application ambient temperature | 0-40℃ |
Application environment humidity | 0-95% |
Fire protection requirements | Materials meet UL 94V0 rating |
Environmental requirements | Materials comply with Rohs, WEEE requirements |
Safety requirements | Comply with IEC62368 international standard design requirements |
Burn-in cabinet | Burn-in bits/cabinet | 9 bits/cabinet |
Burn-in bits/layer | 3 bits/layer |
Burn-in product power | 40kW/bit |
Burn-in product input voltage | 200-1000Vdc/bit |
Burn-in product input current | 100A/bit |
Burn-in Product Load Category | 35kW/bit |
Burn-in product output voltage | Three-phase five-wire |
Burn-in product output current | 80A/bit |
AC Connector Type | PA120 (L1/ L2/ L3/N/PE) |
DC Connector Type | MC4 photovoltaic connector (PV+/PV-/4 groups) |
Signal Connector Type | RJ45 (network port) |
Bit Status Indicator | No |
Input power | 380kW |
Feedback power | 315kW |
Constant temperature range | Room temperature+5°C-60°C |
Constant temperature accuracy | ±5°C |
Number of temperature control points | 5 |
Open type | Sliding door/folding door/side door |