System | System structure | 1 control cabinet + 2 burn-in cabinets + 4 trolleys |
Overall size | 3800*1800*1900mm | |
Total floor area | 3800*2500mm(Including operation area) | |
Total input voltage | Three-phase five-wire system 220Vac (rated) | |
Total input current | 200A | |
Total input power | 100kW | |
Application ambient temperature | 0-40℃ | |
Application environment humidity | 0-95% | |
Fire protection requirements | Materials meet UL 94V0 rating | |
Environmental requirements | Materials comply with Rohs, WEEE requirements | |
Safety requirements | Comply with IEC62368 international standard design requirements | |
Burn-in cabinet | Burn-in bits/cabinet | 16 bits/cabinet |
Burn-in product power | 18kw/bits | |
Burn-in product input voltage | 220Vac (single phase)/380Vac (three phase) | |
Burn-in product input current | 32A/bit | |
Burn-in Product Load Category | 15kW/bit | |
Burn-in product load current | 100-800Vdc | |
Auxiliary voltage of Burn-in products | 50A/bit | |
Auxiliary current of Burn-in products | Universal plug (L1/ L2/ L3/N/PE) | |
Power Connector Type | Gb DC charging interface | |
Signal Connector Type | RJ45 | |
Input power | 288kW | |
Feedback power | 240kW | |
Constant temperature range | Room temperature | |
Number of temperature control points | 5 | |
Volume size | 2050*600*1900mm | |
Dimensions in the product area | 1800*1600mm | |
Product area layers | 4th floor | |
Bit space size | 450*420mm | |
Minimum floor height | 250mm | |
Top floor height | 1350mm | |
Cooling method | Air cooling | |
Material | 1.5mm cold rolled sheet |