Temperature-Controlled Outdoor Storage Charging And Discharging Aging Cabinet
Outstanding functions
Burn-in cabinet structure and Burn-in quantity planning | Trolley size (mm) | L2050*W880*H2050mm (size of a single Burn-in cabinet) |
Number of trolley layers | 4 layers, product area depth 400mm, (12 Burn-in positions per layer) | |
Trolley height | 350mm | |
Load area cooling method | Top turbine exhaust fan top row type (easy to control the ambient temperature) | |
Introduction to energy recovery module configuration, power of the tested power supply and Burn-in quantity | Energy recovery module control method | RS485 communication mode, upper computer RS232 communication mode |
Number of installed energy consumption modules | 8 sets of 8CH modules per layer, 32 sets of Burn-in cabinet need to be installed | |
Energy recovery module isolation method | Electronic load module channel adopts photoelectric isolation (communication and power supply isolation) | |
Number of installed energy recovery modules | 4 sets of 8CH energy recovery modules per floor, 8 sets of the entire Burn-in cabinet need to be installed, 6 sets of 5KW single phase grid-connected inverter modules are installed | |
Energy recovery module design framework | No relay, long-life design scheme (independent intellectual property rights) | |
Number of burn-in products in the whole cabinet | Single cabinet Burn-in 8 DC output (50W/100V/5A) AC output (220V/500W) below 32 energy storage power supplies | |
Introduction of electric control and temperature control device for power Burn-in cabinet | Wiring | Customer specified interface; input port is pin socket |
Panel function keys | Input AC voltage display, start switch, emergency stop switch | |
Way to control | The electric control includes manual/automatic switching, and it is monitored by the computer in real time when it is Burn-in.The electric control cabinet can expand the automatic switching function of AC voltage | |
Safety protection | Equipment grounding protection, leakage switch protection, smoke alarm automatic power-off protection, etc. | |
Introduction to the main functions of the system | Use programmable electronic load module to monitor output terminal voltage, current and power parameters | |
Dedicated monitoring software for Burn-in enjoys free final upgrade service, powerful expansion function, saving repeated investment in equipment | ||
Burn-in parameters, time setting, ON/OFF sequence editing (test of the product being tested on and off), support for automatic voltage switching, load conversion and other functions can be programmed (Burn-in parameters can be automatically switched in a fixed time period) | ||
The function of automatically turning off the power at the end of the Burn-in of the tested power supply is convenient for unattended | ||
The computer automatically displays the quality of the tested power supply product, and multiple windows in the window are convenient for centralized management, which saves operators and improves production efficiency | ||
The computer can store the Burn-in data report of the tested power supply, the process parameters of the tested power supply are easy to trace | ||
RS232 to RS485 adopts photoelectric isolation converter to improve communication reliability and prevent lightning damage to equipment | ||
Each computer can monitor 18 devices at the same time, (each serial port can connect to 63 slaves, and each computer supports up to 18 serial ports) | ||
The power Burn-in monitoring software has a built-in help file, which is convenient for solving operation questions immediately |