Specifications
Brand Name :
Air Giant
Model Number :
AG227SP-16.6;AG227SP-28.3;AG227SP-40;AG227SP-49;AG227SP-52;AG227SP-50;AG227SP-60;AG227SP-70;AG227SP-80;AG227SP-90;AG227SP-100;AG227SP-120;AG227SP-150;AG227SP-103;AG227SP-147;AG227SP-153;AG227SP-160;AG227SP-170
Certification :
UL(Urldorwri1er Laboratories Irlc);TPED;GB;DOT
Place of Origin :
China
MOQ :
1 set
Price :
negotiation
Payment Terms :
L/C, D/P, T/T, Western Union, Paypal, Credit card
Supply Ability :
28000 sets per week
Delivery Time :
10-15 working days
Packaging Details :
Plywood outer box with bubble bag or paper
Model No. :
AG227SP-16.6;AG227SP-28.3;AG227SP-40;AG227SP-49;AG227SP-52;AG227SP-50;AG227SP-60;AG227SP-70;AG227SP-80;AG227SP-90;AG227SP-100;AG227SP-120;AG227SP-150;AG227SP-103;AG227SP-147;AG227SP-153;AG227SP-160;AG227SP-170
Volumn(L) :
16.6;28.3;40;49;52;50;60;70;80;90;100;103;120;147;150;153;160;170
Working pressure :
2.5Mpa;4.2Mpa
Start mode :
Manual and electromagnetic start
Color :
Red
System type :
Single bottle and single area; Multi bottle single zone and multi bottle multi zone
Description

UL Certification 70L FM200 Fire Extinguishing System Without Residue

Description of UL FM200 Fire Extinguishing System

Heptafluoropropane (HFC-227ea/FM200) is a clean and safe fire extinguishing agent that can be used in fully submerged automatic fire extinguishing systems, replacing Halon 1301, and maintaining the excellent fire extinguishing performance of Halon fire extinguishing agent without causing any environmental problems.

The safety of the heptafluoropropane (HFC-227ea/FM200) fire extinguishing system in total flooding applications is safer than Halon 1301, with a safe exposure concentration of 9% accepted by the US Environmental Protection Agency (EPA). Meanwhile, the ozone depletion value (ODP) of HFC-227ea is 0, non-conductive, clean, and residue free.

UL Certification 70L FM200 Fire Extinguishing System Without Residue


Main Parameter of UL TPED series cylinders

Model No. Nominal pressure (bar) Nominal volume(L) Filling volume (kg)

Caliber

(mm)

Weight

(kg)

Min. Max.
AG227SP-25-40M 25 40 19.2 44.8 49 47
AG227SP-25-50M 25 50 24.0 56.0 49 58
AG227SP-25-60M 25 60 28.8 67.2 49 65
AG227SP-25-70M 25 70 33.6 78.4 49 72
AG227SP-25-80M 25 80 38.4 89.6 49 80
AG227SP-25-90M 25 90 43.2 100.8 49 94
AG227SP-25-100M 25 100 48.0 112.0 49 100
AG227SP-25-120M 25 120 57.6 134.4 49 113
AG227SP-25-150M 25 150 72.0 168.0 49 134
AG227SP-25-40K 25 40 19.2 44.8 33 41
AG227SP-25-50K 25 50 24.0 56.0 33 52
AG227SP-25-60K 25 60 28.8 67.2 33 59
AG227SP-42-40M 42 40 19.2 44.8 49 47
AG227SP-42-50M 42 50 24.0 56.0 49 58
AG227SP-42-60M 42 60 28.8 67.2 49 65
AG227SP-42-70M 42 70 33.6 78.4 49 72
AG227SP-42-80M 42 80 38.4 89.6 49 80
AG227SP-42-90M 42 90 43.2 100.8 49 94
AG227SP-42-100M 42 100 48.0 112.0 49 100
AG227SP-42-120M 42 120 57.6 134.4 49 113
AG227SP-42-150M 42 150 72.0 168.0 49 134
AG227SP-42-170M 42 170 81.6 190.4 49 149
AG227SP-42-40K 42 40 19.2 44.8 33 41
AG227SP-42-50K 42 50 24.0 56.0 33 52
AG227SP-42-60K 42 60 28.8 67.2 33 59



Features of UL FM200 Fire Extinguishing System

  • Efficient: Heptafluoropropane gas can quickly extinguish fires, quickly suppress the fire, and effectively control the fire situation in a short period of time.
  • Environmental protection: Heptafluoropropane gas has a short residence time in the atmosphere, has no destructive effect on the ozone layer and greenhouse gases, and will not cause damage to the environment and human body.

  • No residue: After extinguishing with heptafluoropropane gas, there will be no residue left, and it will not affect equipment and valuable items.

  • Automatic control: The system can automatically detect fires and trigger fire extinguishing devices, making operation simple and convenient


Application of UL FM200 Fire Extinguishing System


Fire suppression system HFC-227ea can be used in normal commercial and industrial settings. Typical areas that can be protected by this system include:

  • Bank vault
  • Laboratory
  • Rare Book Library
  • Electronic data room
  • Telecom switching room
  • Studio
  • Communication Center
  • Transformer room and distribution room
  • Electrical control room
  • Auxiliary power room
  • Combustible liquid storage room
  • Computer room

UL Certification 70L FM200 Fire Extinguishing System Without Residue


Packages of UL FM200 Fire Extinguishing System


We always pack it with polyfoam firstly and then put it into a wooden case. Sometimes, in order to meet with customers or the safety requirement, we will make a pallet for the goods.


UL Certification 70L FM200 Fire Extinguishing System Without Residue

Send your message to this supplier
Send Now

UL Certification 70L FM200 Fire Extinguishing System Without Residue

Ask Latest Price
Brand Name :
Air Giant
Model Number :
AG227SP-16.6;AG227SP-28.3;AG227SP-40;AG227SP-49;AG227SP-52;AG227SP-50;AG227SP-60;AG227SP-70;AG227SP-80;AG227SP-90;AG227SP-100;AG227SP-120;AG227SP-150;AG227SP-103;AG227SP-147;AG227SP-153;AG227SP-160;AG227SP-170
Certification :
UL(Urldorwri1er Laboratories Irlc);TPED;GB;DOT
Place of Origin :
China
MOQ :
1 set
Price :
negotiation
Contact Supplier
UL Certification 70L FM200 Fire Extinguishing System Without Residue

Guangdong Air Giant Fire Equipment Co.,Ltd.

Verified Supplier
3 Years
guangzhou
Since 2022
Business Type :
Manufacturer, Exporter, Trading Company
Total Annual :
5000000-10000000
Employee Number :
10~50
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement