Specifications
Brand Name :
Air Giant
Model Number :
QMP40/4.2, QMP70/4.2, QMP100/4.2, QMP120/4.2, QMP150/4.2, QMP180/4.2
Certification :
CAL,CMA,CNAS,ILAC-MRA,CCC
Place of Origin :
China
MOQ :
1 set
Price :
negotiation
Payment Terms :
L/C, D/P, T/T, Western Union, Paypal, Credit card
Supply Ability :
28000 sets per week
Delivery Time :
10-15 working days
Packaging Details :
Plywood outer box with bubble bag or paper
Storage Pressure :
4.2MPa
Spraying Time :
≤10s
Filling Density :
≤1420kg/m3
Nominal Pressure :
5.3MPa
Test Pressure :
8.4MPa
Working Power :
DC 24V 1.6A
Working Temperature :
0℃~50℃
Protected Zone Range: :
Proportion: ≤800m² Volume: ≤3600m³
Starting Mode :
Automatic, Electrical Manual, Mechanical Manual
Cylinder Volume :
40L、70L、100L、120L、150L、180L
Description

Cafss insulated Novec1230 fire suppression system without residue for museum

Perfluorohexadone automatic fire extinguishing system, also known as Novec1230 / FK-5-1-12 automatic fire extinguishing system, is a gas fire extinguishing system based on perfluorocarbons, which is used to extinguish dangerous chemicals and other flammable and explosive objects.

The perfluorohexadone automatic fire extinguishing system uses the colorless and odorless perfluorocarbon Novec1230 / FK-5-1-12 as the fire extinguishing agent, which has the following characteristics:

1. Environmental protection: Novec1230 / FK-5-1-12 is a non-toxic, colorless, tasteless, non-corrosive, non-conductive and non-explosive fire extinguishing agent, which can protect equipment and environment from damage.

2. High efficiency: the PFH automatic fire extinguishing system can extinguish the fire quickly in a short time without any damage to the protected equipment.

3. High safety: Novec1230 / FK-5-1-12 fire extinguishing agent has high stability, is not easy to burn, and will not produce harmful substances. Therefore, the use of this fire extinguishing system can effectively ensure the safety of personnel and equipment.

4. Strong flexibility: PFH automatic fire extinguishing system can flexibly adapt to different fire extinguishing requirements, and is applicable to various sizes and types of places.

Filling Density: ≤1420kg/m3 Nominal Pressure: 5.3MPa
Test Pressure: 8.4MPa Working Power: DC 24V 1.6A
Working Temperature: 0℃~50℃

Protected Zone Range:

Proportion: ≤800m²

Volume: ≤3600m³

Starting Mode: Automatic, Electrical Manual, Mechanical Manual Cylinder Volume: 40L,70L,100L,120L,150L,180L

Working Principle

The working principle of the PFH automatic fire extinguishing system is that when a fire occurs, the system detector detects the fire source, and the controller will automatically open the vent valve to release the Novec1230 /FK-5-1-12 fire extinguishing agent from the pipe network and enter the fire extinguishing area to extinguish the fire. The fire extinguishing system is an ideal fire extinguishing device with simple operation, high automation and fast and effective fire extinguishing.

Here is the illustration of working principle to whole system.

Cafss Insulated Novec1230 Fire Suppression System  Without Residue For Museum

Components

Actually, a complete fire suppression system has two parts, one is fire extinguishing part and the other is electrical elements part. Because there is a part focus on eletrical elements, so here will not talk about it anymore. The fire extinguishing part is list out as followings:

1/ Novec1230 cylinder

2/ Container valve

3/ Solenoid actuator

4/ Flexible hose

5/ Liquid flow check valve

6/ Cylinder frame

7/ Manifold

8/ Safety valve

9/ Pressure switch

Cafss Insulated Novec1230 Fire Suppression System  Without Residue For Museum

Application

The pipe network type Novec1230 fire suppression system is suitable for a lot of places and several kinds of fires. The followings are some examples for customer as reference:

- Telecommunications and data processing

- Switch gear rooms

- Military applications and cell sites

- High-tech medical application

- Computer rooms

- Telecommunication centers

- Records and data archives

- Testing/imaging equipment

- Reference material

- Chemical laboratories

Cafss Insulated Novec1230 Fire Suppression System  Without Residue For Museum

Advantages

This system has a cylinder frame, whose shape is similar to a cabinet, so this system is called cabinet pipe network type Novec1230 fire suppression system. Besides, here is going to list out the advantages of this system.

1/ Place saving. This fire suppression system requires a separated room outside the protected zone, and will not occupy the places of the protected zone.

2/ Easy installation. A few components and an easy structure make the system install easily.

3/ Convenient transportation. Because of a few components and careful package, the transportation will be very convenient and safe.

Packages

We always pack it with polyfoam firstly and then put it into a wooden case. Sometimes, in order to meet with customers or the safety requirement, we will make a pallet for the goods.

Cafss Insulated Novec1230 Fire Suppression System  Without Residue For Museum

Send your message to this supplier
Send Now

Cafss Insulated Novec1230 Fire Suppression System Without Residue For Museum

Ask Latest Price
Watch Video
Brand Name :
Air Giant
Model Number :
QMP40/4.2, QMP70/4.2, QMP100/4.2, QMP120/4.2, QMP150/4.2, QMP180/4.2
Certification :
CAL,CMA,CNAS,ILAC-MRA,CCC
Place of Origin :
China
MOQ :
1 set
Price :
negotiation
Contact Supplier
video
Cafss Insulated Novec1230 Fire Suppression System  Without Residue For Museum

Guangdong Air Giant Fire Equipment Co.,Ltd.

Verified Supplier
3 Years
guangzhou
Since 2022
Business Type :
Manufacturer, Exporter, Trading Company
Total Annual :
5000000-10000000
Employee Number :
10~50
Certification Level :
Verified Supplier
Contact Supplier