Certificate: CE Certified
Output Power: 30KW
Charging Standards: CCS
Warranty: 12 Months
Input voltage: AC380V 20%
Installation: Floor-standing
OCPP: OCPP 1.6J
Application: Commercial Places
Protection level: IP54
Supply Ability: 1000 Piece/Pieces per Month
Packaging Details: carton box outside
Port: Shanghai/Shenzhen
Lead Time:
Quantity(Pieces) | 1 - 2 | 3 - 50 | >50 |
Est. Time(days) | 7 | 15 | To be negotiated |
Main features of DC fast chargers for electric vehicles
1. High efficiency
2. High power density
3. Input high voltage shock resistance
4. Modular design
5. One machine with four charging functions
No | Item | Data | ||||||
1 | AC Power Input Rating | TN-S, 380V±15%, 50/60Hz | ||||||
2 | Power Wiring | 3-Phase, 5 Wires - L1/L2/L3, Neutral plus PE | ||||||
3 | DC Voltage Output | 200 ~ 750VDC | ||||||
4 | Charging Gun | Meet GB/T 20234.3-2015, 1/2-Gun (with temp. detector), 5m cable | ||||||
5 | DC Power Output Rating | 30kW | ||||||
6 | The Maximum Output Current | 75A | ||||||
7 | PF (Power Factor) | ≥98% (@50% ~ 100% full load output power) | ||||||
8 | THD-I | ≤5% | ||||||
9 | Peak Efficiency | ≥96% (@750V, 50% ~ 100% full load, rated input Voltage) | ||||||
10 | Voltage Stabilized Accuracy | <0.5% | ||||||
11 | Current Stabilized Accuracy | <±1% | ||||||
12 | Output Voltage Error | ±0.5% | ||||||
13 | Output Current Error | ≤±1% (when output current ≥ 30A); ≤±0.3A (when output current < 30A) | ||||||
14 | Ripple Factor | ≤±0.5%(RMS) | ||||||
15 | Electric energy measurement method | Measuring DC output electric energy | ||||||
16 | Auxiliary Power Supply | 30W, 12/24 VDC switchable | ||||||
17 | Connector Mechanical Operating Life | ≥10000 times | ||||||
18 | User Interface & Control | |||||||
19 | Charging Control | Plug and Play, RFID Card or App | ||||||
20 | Human-Machine Interface | 7-inch LCD Touchable Screen | ||||||
21 | Indicators | 4 LED indicators-Power/ Fault / Charging A / Charging B | ||||||
22 | External Communication | Either ethernet | ||||||
23 | OCPP Protocol (Optional) | OCPP 1.6 | ||||||
24 | Environmental | |||||||
25 | Storage Temperature | -40 to 75℃ ambient, derating output in 50~55℃ | ||||||
26 | Operating Temperature | -20 to 55℃ ambient | ||||||
27 | Operating Humidity | Up to 95% non-condensing | ||||||
28 | Altitude | ≤2000m | ||||||
29 | Cooling Method | Forced air cooling | ||||||
30 | Protection | |||||||
31 | Over Voltage Protection | Yes | ||||||
32 | Over Load Protection | Yes | ||||||
33 | Over-temp Protection | Yes | ||||||
34 | Under Voltage Protection | Yes | ||||||
35 | Mechanical | |||||||
36 | Protection Ratings | IP 54 | ||||||
37 | Equipment Dimension (H×W×D,) | 1800mm × 700mm × 600mm | ||||||
38 | Equipment Weight | ≤ 320kg | ||||||
39 | Enclosure Material | Metal | ||||||
40 | Color | Grey (The color is close to RAL 7032) |