2Volt 800Ah Deep Cycle Gel Battery Full Capacity Long Service Life
Description
Deep Cycle Gel battery is a battery in which the electrolyte is in gel state, which belongs to a development classification of lead-acid battery, the method is to add gelling agent to sulfuric acid, so that the sulfuric acid electrolyte becomes gel state. Gel battery with a smaller industrial cost, manufacturing a higher quality battery, its discharge curve is straight, the inflection point is high, its energy and power than conventional lead-acid battery is more than 20%. Lead-acid batteries are characterized by electrolyte that does not leak out of the battery terminals or casing during normal operation. The special absorption partition keeps the acid inside and there is no free acid inside the battery, so the battery can be placed in any position. Due to the unique gas compound system that converts the generated gas into water, there is no need to add water during the use of the battery.
Model | Nominal Voltage | Capacity C10 | Weight | Dimension | ||
Height | Length | Width | ||||
V | Ah | kg | mm | mm | mm | |
JGFM 100-2 | 2 | 100 | 7.2 | 205 | 172 | 102 |
JGFM 150-2 | 2 | 150 | 9 | 320 | 172 | 102 |
JGFM 200-2 | 2 | 200 | 13 | 329 | 171 | 111 |
JGFM 300-2 | 2 | 300 | 18 | 330 | 171 | 151 |
JGFM 400-2 | 2 | 400 | 25 | 329 | 211 | 176 |
JGFM 500-2 | 2 | 500 | 28 | 331 | 241 | 172 |
JGFM 600-2 | 2 | 600 | 35 | 331 | 301 | 175 |
JGFM 800-2 | 2 | 800 | 48 | 333 | 410 | 175 |
JGFM 1000-2 | 2 | 1000 | 62 | 329 | 470 | 175 |
JGFM 1500-2 | 2 | 1500 | 96 | 343 | 401 | 351 |
JGFM 2000-2 | 2 | 2000 | 123 | 343 | 491 | 351 |
JGFM 3000-2 | 2 | 3000 | 180 | 341 | 712 | 353 |
Product Features
Advantages
Application
Power, nuclear power station backup power supply
Compliant standards
Use of Deep Cycle Gel Battery
Discharge: 1) 12V battery charging and discharging, 250Ah battery with a current of no more than 25A for 10 hours to discharge until the battery termination voltage of 10.8V or more, do not over discharge.
2) During the discharge process, measure and record the battery voltage, discharge current and ambient temperature every hour, pay attention to the change of ammeter and battery voltage at any time, when the voltage drops to about 12.0V, change to half an hour test. When the measured voltage is 10.8v, stop discharging, open the discharge switch, the discharge is over. And record the discharge termination time, battery voltage, ambient temperature.
3) After discharge, the battery should be recharged in time, to prevent acidification of the poles, the discharge-charging interval should not exceed 8 hours, so it must be balanced within 8 hours to replenish the electricity, the average charging voltage is set to 14.1V (the average of the measured value of the positive and negative terminals of the battery at 25℃), and the maximum charging current is set to 0.25C10A. The battery will run normally with the float charging voltage of 13.5V. Battery 13.5V.
Temperature compensation: The above current and voltage setting values are the standard values when the ambient temperature is 25℃, if the gel battery working temperature is beyond the range of 20℃-30℃, the floating charge and average charge voltage should be corrected accordingly, the corrected voltage is, that is, for every 1℃ increase in temperature, the floating charge voltage is reduced by 5.5mV, and for every 1℃ decrease in temperature, the floating charge voltage is increased by 5.5mV.