Agriculture percent Timer with 60seconds for irrigation system
Timing Rangs:
SYM | DIAL RANGE | SYM | DIAL RANGE |
01 | 15 Sec | 07 | 10 Min |
02 | 30 Sec | 08 | 15 Min |
03 | 60 Sec | 09 | 30 Min |
04 | 120 Sec | 10 | 60 Min |
05 | 4 Min | 11 | 120 Min |
06 | 5 Min |
Input Votage/Frequency:
120VAC(+10,-15%)50/60HZ
240VAC(+10,-15%)50/60HZ
Power Consumption
1.2watts
Release Value of input Voltage
10%
Contact Rating:
CONTROL VOLTAGE | CONTAC RATING |
120VAC | 9A,120VAC~ RESISTIVE INDUCTIVE.1/6HP@120VAC |
240VAC | 5A,240VAC~ RESISTIVE INDUCTIVE.1/2HP@/240VAC |
Electrical Endurance
30000 cycles
Frequency of Operation
Note operating frequency,depends on Time RANGE
Mechanical Endurance
30000 cycles
Contact material
Silver Tin Oxide
The CYCL-TIME Percent Timer series is an accurate,econimical,enclosed percentage timer designed for use in application where a repetitive ON time for a fixed cycle needs to be variable.
The CYCL-TIME Percent Timer is ideally suited for:
Irrigation controls
Chemical feeding
Programed temperature controls
Electric heaters,ovens
Motor controls
Lubrication systems
The CYCL-TIME Percent Timer series is a panel mounted unit with exposed dial.The heavy duty front dial plate has 4 mounting studs for simple and secure mounting studs for simple and secure mounting to panels up to 1/4 inch thick.The load relays are enclosed for environmental protection.Electric connections are made to captive screw terminals on the rear of the unit.
Operation:
Percentage settings are made with a knob and a dial on the front of the unit.Settings may be made or changed with the timer operating.At 100 percent setting,terminals 2 and 3 are closed continuously.At zero percent setting,terminals 2 and 3 are open continuously.
Operating Temp:-10 to +140 Deg.F
Relative Humidity:25% to 85%
Mounting Position:Flush,Panel mount
Degree of Protection:IP51 for panel surface only,to be enclosed in suitable enclosure
Type of Insulation:Functional,Pollution Degree 2
Overvoltage category:Cat 3,pollution Degree 2
Impulse test:120VAC~/1500VAC,240VAC~/2500VAC
Dielectric Test:1440VAC~,1 minute
EMC immunity:8KV Static Air Discharge
Prospective current:100A
Unit function:Repeat cycles relay
Recovery time:Complete operating cycle
Min control umpulse:<10MS
Setting Accuracy:1% of total time cycle
Repeatablity:±1% of total time cycle
Influence effects:votage error: Max.±0.5% Temperature erroe:max.±2%