Stainless Steel Antifraying Exhaust Fan Big Size Power Plant Fan
Introduction
The 5-06 series fan can be used in the feeding system of 2-670t/h steam boiler in thermal power plants, it can also meet the requirements of the high-pressure head performance parameters of the fluidized bed furnace.
The casing is a volute welded by ordinary steel plates.The converging and streamlined air inlet is made into a unitary structure and bolted to the inlet side of the fan.
Product Advantages
The bearing housing is equipped with a thermometer and an oil level indicator (only the induced draft fan). The lubricating oil uses 46# mechanical oil, and the oil quantity is implemented according to the oil level mark. When the No8-16 integral cylindrical bearing housing uses dry oil, the oil retaining plate should be added to the ball side of the bearing housing, and the fixing grooves communicate with each other. The induced draft fan is equipped with a water cooling device, so a water supply pipe must be installed.
Technical data
series | model | Rotation Speed (r/min) | Total Pressure (Pa) | Air Capacity (m³/h) | Power (kW) |
---|---|---|---|---|---|
5-06 | 8D | 1450 | 2592~1989 | 12028~20607 | 15 |
10D | 1450 | 4051~3108 | 23493~40249 | 55 | |
11D | 1450 | 3036~2329 | 31269~53571 | 55 | |
12.4D | 1450 | 3858~2960 | 44792~76740 | 90 |
FAQ
1. What parameters need to be provided when you design the Heat Dissipation Power Plant Blower Fan?
Answers: Air flow, total pressure or static pressure, inlet temperature, local voltage and frequency, Altitude etc.
If there is flammable and explosive gas, or big dust loading in the medium, please also inform the designer.
2. How about your company’s pre-sales service and after-sales service?
Answers: Before our cooperation, we have the professional technical team to help you make the technical solution according to your working condition, to make sure the centrifugal fan efficiency operation.
After sales service, we will offer 12 months’ repairing service, and provide lifelong follow-up services. Besides, our engineers are available for going abroad to offer the repairing service.
3. Does your company have qualifications?
Answers: SIMO Blower has obtained ISO 9001-2008, CE, BV certifications and so on.
Provide the required centrifugal fan parameters, SIMO Blower can be customized according to requirements, the supply speed is fast, we will quote you in real time, the price is favorable!