Aluminium Alloyed High Air Flow Forward Blast Furnace Boiler Fan
Introduction
The 5-06 series fan can be used in the feeding system of 2-670t/h steam boiler in thermal power plants, it can also meet the requirements of the high-pressure head performance parameters of the fluidized bed furnace.
This series of fans can also be used for dust removal, mine ventilation and general ventilation systems. The blower delivers air, and the induced draft fan delivers flue gas or gas containing foreign particles.
It can be used for more than four years when the concentration of impurities is less than 200 mg/m3.
Technical data
series | model | Rotation Speed (r/min) | Total Pressure (Pa) | Air Capacity (m³/h) | Power (kW) |
---|---|---|---|---|---|
5-06 | 8D | 1450 | 2592~1989 | 12028~20607 | 15 |
10D | 1450 | 4051~3108 | 23493~40249 | 55 | |
11D | 1450 | 3036~2329 | 31269~53571 | 55 | |
12.4D | 1450 | 3858~2960 | 44792~76740 | 90 |
Product Features
If it contains a lot of impurities, it also can be used, but it will shorten the service life.
The maximum operating temperature of the induced draft fan must not exceed 250°C.
The performance of the fan is expressed by parameters such as fan flow, full pressure, spindle speed, shaft power and efficiency.
FAQ
1.Q: What parameters need to be provided when you design the industrial centrifugal fans?
A: Air flow rate(m3/h), Total pressure(Pa) or Static pressure(Pa), Inlet temperature(°C), Voltage and frequency on the working site.
2. Q:What is your delivery time?
A:15-35workdays, depending on the model of the fan.
3.Q:Are you manufacturer or trading company?
A:We are the professional manufacturer of centrifugal fans , over 65 years production experience and sales experience.
4.Q:What's your MOQ?
A:The MOQ is 1set,but larger quantity, lower price.
5.Q: What’s your warranty?
A: 12 months after arrival of the goods on site.
6.Q:How do you control the product's quality?
A:All the products have quality testing and dynamic balance before delivery.