Side by Side Cartridge Chemcial Anchor Adhesive For Thread Rods
Chemical anchor adhesive, epoxy injection mortar, Chemical fixing glue,
Chemical anchoring system used for anchoring and rebar connections in concrete.
Item #: FixingChor142
Capacity: 420ml
Materials: Epoxy
Mixing Ratio: 1:1
Product Description:
Adopted with modified epoxy resin and composite materials, XQ-IME Injection Anchoring Adhesive is a two-component, Styrene Free system for use as a high strength, non-shrink anchor grouting material. Its advantage on steel bar planting has been proved by many testimonies. Compares with other adhesive, it is a new high performance, Eco-friendly anchoring adhesive which has strong bonding strength and high efficiency as well as irritation free and low odor.
Advantages
Application:
of curtain wall.
Testing project | Condition | Index | ||
Gel Performance (According to China National Standard GB50728-2011) | ||||
Splitting Tensile Strength (MPa) | Under (23±2)℃,(50±5)%RH, tested by loading speed of 2mm/min | ≥8.5 | ||
Flexural Strength (MPa) | ≥50 (no fragment damage) | |||
Compressive Strength (MPa) | ≥60 | |||
Bonding Capacity (According to China National Standard GB50728-2011) | ||||
Steel-Steel Tensile Shear Strength (MPa) | (23±2)℃,(50±5)%RH | ≥10 | ||
Bonding strength of Ribbed steel bar (or screw) with concrete under constrain drawing condition | (23±2)℃ (50±5)%RH | C30,Ф25,L=150mm | ≥11 | |
C60,Ф25,L=150mm | ≥17 | |||
Steel-Steel T-peeling strength (mm) | (23±2)℃,(50±5)%RH | ≤25 | ||
Non-volatile content | (105±2)℃,(180±5)min | ≥99% | ||
Ageing resistance to heat and humidity 90d | ||||
Reduction rate of tensile strength | Under normal room temperature | ≤12% | ||
(According to China National Standard JGJ145-2013) | ||||
Tensile Strength (after high temperature welding) | Dia12 Grade II steel, C30 concrete Hole dia.16mm, Depth: 150mm | 55.1N, 57.0N, 54.8N |
Approved for anchorings in:
Concrete, cracked and non-cracked Applications
Rebar planting in concrete structures.
Railway or express way modification works
Structure reinforcement
Curtain wall installing
Bridge modification works
Keel fixing in out wall
ATTENTION
- Do not install anchors when the temperature is less than 10°C.
- If the cartridge is not finished, please clean the opening, then put the plug back and cap tightly.
- At temperatures below 10°C should be warmed or stored in temperatures
of 10-30°C for 24hours prior to use to improve product flow and cure.
- If the gelling time expires, please use a new static mixer.
- Do not cut or shorten nozzles.
- It can be used again in the future by replacing the static mixer.
- Please ensure hole is properly cleaned. Hole may be damp but must be free from water.
- Do not install anchors when substrate temperature is less than 0°C.