Laser power meter is used to measure laser power and power stability. We have designed several laser power measurement instruments with the features of accuracy testing, easy operation, etc., which could fully meet customer’s practical needs of laser power and power stability measurement. They are widely used in the research, teaching, medical science, industry and other fields.
Product | Part number | Power range | Main features | |
Thermopile Laser Power Meter | STC-TS series (Wide Range) | STC-TS2+TP100 | 2mW-2W | 1.Wavelength range: 0.19 -20µm 2. Damage threshold: 15kW/cm2 3. Power measurement range:2mW-15W 4. Sensitivity diameter: 14mm 5. Minimum measuring precision:0.1mW |
STC-TS5+TP100 | 5mW-5W | |||
STC-TS15+TP100 | 10mW-15W | |||
STC-TS35+TP100 | 10mW-35W | 1. Wavelength range: 0.19 -25µm 2. Damage threshold: 40kW/cm2 3. Power measurement range: 10mW-50W 4. Sensitivity diameter: 22mm 5. Minimum measuring precision: 0.001W | ||
STC-TS50+TP100 | 10mW-50W | |||
STC-TS100+TP100 | 0.5W-100W | 1. Wavelength range: 0.19 -20µm 2. Damage threshold: 45kW/cm2 3. Power measurement range: 0.5W-100W 4. Sensitivity diameter: 25mm 5. Minimum measuring precision: 0.001W | ||
STC-HS series (High Precision) | STC-HS1+TP100 | 100µW-1W | 1. Wavelength range: 0.19 -15µm 2. Damage threshold: 1.5kW/cm2 3. Power measurement range: 100µW-5W 4. Sensitivity diameter: 8.5mm 5. Minimum measuring precision: 0.01mW | |
STC-HS5+TP100 | 500µW-5W | |||
Hand-held series | STC-HP2 | 10mW-20W | 1.Wavelength range: 0.19-25µm 2.Damage threshold: 40kW/cm2 3.Powe measurement range: 10mW-50W 4.Sensitivity dia.: 22mm | |
STC-HP5 | 0.5W-50W | |||
USB series (multi-channel) | STC-PD100-350-USB STC-PD1000-350-USB STC-PD100-350T-USB STC-PD1000-350T-USB STC-PD20-200-USB STC-PD1000-200-USB STC-PD20-200T-USB STC-PD1000-200T-USB PD3000-350-USB | 1nW-100mW 1nw-1W 1nW-100mW 1nw-1W 1nw-20mW 1nw-1W 1nw-20mW 1nw-1W 1uW-3W | 1. Wavelength range:0.19 -25µm 2. Power range: 1µW-200W 3. Single channel/ multiple channel power measurement 4. PC upper computer software display measurement 5. RS232, RS422 or other communication interface can be customized | |
STC-TS2/ TS5/ TS15-USB STC-TS35/ TS50-USB STC-TS100-USB STC-HS1/ HS5-USB | 100µW-100W | |||
Photoelectric Laser Power Meter | STC-PS100 series (High Precision) | STC-PS100 | 2nW-100mW | 1. Wavelength range: 320-1100nm 2. High precision: ±2% 3. Resolution: 2nW 4. Minimum measuring precision: 0.001nW |
Wavelength range: 0.19 -20µm
Damage threshold: 15kW/cm2
Power measurement range: 2mW-15W
Sensitivity diameter: 14mm
Minimum measuring precision: 0.1mW
SMA905/FC fiber switch connector (Optional)
Part number | STC-TS2+TP100 | STC-TS5+TP100 | STC-TS15+TP100 |
Header Model | STC-TP100 | STC-TP100 | STC-TP100 |
Probe Model | STC-TS2 | STC-TS5 | STC-TS15 |
Power Range | 2 mW - 2 W | 5 mW - 5 W | 10 mW - 15 W |
Sensitive Diameter | 14 mm | 14 mm | 14 mm |
Continuous Measurement Time (<5W) | Unlimited (<2W) | Unlimited | Unlimited |
Continuous Measurement Time (5-15W) | / | / | ≤8 min |
Probe Coating Film | Broadband coating | ||
Probe Material | Thermopile | ||
Wavelength Range | 0.19-20 μm | ||
Max. Average Power Density | 15 kW/cm2 | ||
Sensitivity | 2 mW | 5 mW | 10 mW |
Calibration Uncertainty (k=2) | ±2% | ||
Response Time (0-90%) | <1 sec. | ||
Linearity | ±1% | ||
Power Supply | 18650 (2 batteries) | ||
Overall Weight | 1.454 kg | ||
Cooling Method | Air cooling | ||
Computer Interface | USB 1.1 and USB 2.0 | ||
Instrument Power | 100-240 VAC, 50/60 Hz, DC 12V-3.34A | ||
Temperature (Operating) | 5°C - 45°C (41°F - 113°F) | ||
Temperature (Storage) | -20°C - 70°C (-4°F - 158°F) |
Wavelength range: 0.19 -25µm
Damage threshold: 40kW/cm2
Power measurement range: 10mW-50W
Sensitivity diameter: 22mm
Minimum measuring precision: 0.001W
SMA905/FC fiber switch connector (Optional)
Part Number | STC-TS35+TP100 | STC-TS50+TP100 |
Header Model | STC-TP100 | STC-TP100 |
Probe Model | STC-TS35 | STC-TS50 |
Power Range | 10 mW - 35 W | 10 mW - 50 W |
Sensitive Diameter | 22 mm | 22 mm |
Continuous Measurement Time (<10 W) | Unlimited | Unlimited |
Continuous Measurement Time (10-50W) | ≤5 min (10-35W) | ≤5 min (10-50W) |
Probe Coating Film | Broadband coating | |
Probe Material | Thermopile | |
Wavelength Range | 0.19-25 μm | |
Max. Average Power Density | 40 kW/cm2 | |
Sensitivity | 10 mW | |
Calibration Uncertainty (k=2) | ±2% | |
Response Time (0-90%) | <1 sec. | |
Linearity | ±1% | |
Power Supply | 18650 (2 batteries) | |
Overall Weight | 1.926 kg | |
Cooling Method | Air cooling | |
Computer Interface | USB 1.1 and USB 2.0 | |
Instrument Power | 100-240 VAC, 50/60 Hz, DC 12V-3.34A | |
Temperature (Operating) | 5°C - 45°C (41°F - 113°F) | |
Temperature (Storage) | -20°C - 70°C (-4°F - 158°F) |
Wavelength range: 0.19 -20µm
Damage threshold: 45kW/cm2
Power measurement range: 0.5W-100W
Sensitivity diameter: 25mm
Minimum measuring precision: 0.001W
Part Number | STC-TS100+TP100 |
Header Model | STC-TP100 |
Probe Model | STC-TS100 |
Power Range | 0.5 W - 100 W |
Sensitive Diameter | 25 mm |
Continuous Measurement Time (<80 W) | 2 h |
Continuous Measurement Time (80-100 W) | ≤8 min |
Probe Coating Film | Broadband coating |
Probe Material | Thermopile |
Wavelength Range | 0.19-20 μm |
Max. Average Power Density | 45 kW/cm2 |
Sensitivity | 0.1 W |
Calibration Uncertainty (k=2) | ±2% |
Response Time (0-90%) | <7 sec. |
Linearity | ±1% |
Power Supply | 18650 (2 batteries) |
Cooling Method | Fan cooling |
Computer Interface | USB 1.1 and USB 2.0 |
Instrument Power | 100-240 VAC, 50/60 Hz, DC 12V-3.34A |
Temperature (Operating) | 5°C - 45°C (41°F - 113°F) |
Temperature (Storage) | -20°C - 70°C (-4°F - 158°F) |
Wavelength range: 0.19 -15µm
Damage threshold: 1.5kW/cm2
Power measurement range: 100µW-5W
Sensitivity diameter: 8.5mm
Minimum measuring precision: 0.01mW
SMA905 fiber switch connector (Optional)
Part Number | STC-HS1+TP100 | STC-HS5+TP100 |
Header Model | STC-TP100 | STC-TP100 |
Probe Model | STC-HS1 | STC-HS5 |
Power Range | 100µW - 1 W | 500µW - 5 W |
Sensitive Diameter | 8.5 mm | 8.5 mm |
Probe Coating Film | Broadband coating | |
Probe Material | Thermopile | |
Wavelength Range | 0.19-15 μm | |
Max. Average Power Density | 1.5 kW/cm2 | |
Sensitivity | 100µW | 500µW |
Calibration Uncertainty (k=2) | ±2% | |
Response Time (0-90%) | <1 sec. | |
Linearity | ±0.5% | |
Power Supply | 18650 (2 batteries) | |
Overall Weight | 1.434 kg | |
Cooling Method | Air cooling | |
Computer Interface | USB 1.1 and USB 2.0 | |
Instrument Power | 100-240 VAC, 50/60 Hz, DC 12V-3.34A | |
Temperature (Operating) | 5°C - 45°C (41°F - 113°F) | |
Temperature (Storage) | -20°C - 70°C (-4°F - 158°F) |
Wavelength range: 0.19 -20µm
Power measurement range: 2mW-15W
Single channel/ multi-channel power measurement
PC upper computer software display measurement
Model | STC-TS2-USB | STC-TS5-USB | STC-TS15-USB |
Power Range | 2 mW - 2 W | 5 mW - 5 W | 10 mW - 15 W |
Sensitive Diameter | 14 mm | 14 mm | 14 mm |
Continuous Measurement Time (<5W) | Unlimited (<2W) | Unlimited | Unlimited |
Continuous Measurement Time (5-15W) | / | / | ≤8 min |
Probe Coating Film | Broadband coating | ||
Probe Material | Thermopile | ||
Wavelength Range | 0.19-20 μm | ||
Max. Average Power Density | 15 kW/cm2 | ||
Sensitivity | 2 mW | 5 mW | 10 mW |
Calibration Uncertainty (k=2) | ±2% | ||
Response Time (0-90%) | <1 sec. | ||
Linearity | ±1% | ||
Cooling Method | Air cooling | ||
Computer Interface | USB 1.1 and USB 2.0 | ||
Temperature (Operating) | 5°C - 45°C (41°F - 113°F) | ||
Temperature (Storage) | -20°C - 70°C (-4°F - 158°F) |
Wavelength range: 0.19 -25µm
Power measurement range: 10mW-50W
Single channel/ multi-channel power measurement
PC upper computer software display measurement
Model | STC-TS35-USB | STC-TS50-USB |
Power Range | 10 mW - 35 W | 10 mW - 50 W |
Sensitive Diameter | 22 mm | 22 mm |
Continuous Measurement Time (<10 W) | Unlimited | Unlimited |
Continuous Measurement Time (10-50W) | ≤5 min (10-35W) | ≤5 min (10-50W) |
Probe Coating Film | Broadband coating | |
Probe Material | Thermopile | |
Wavelength Range | 0.19-25 μm | |
Max. Average Power Density | 40 kW/cm2 | |
Sensitivity | 10 mW | |
Calibration Uncertainty (k=2) | ±2% | |
Response Time (0-90%) | <1 sec. | |
Linearity | ±1% | |
Cooling Method | Air cooling | |
Computer Interface | USB 1.1 and USB 2.0 | |
Temperature (Operating) | 5°C - 45°C (41°F - 113°F) | |
Temperature (Storage) | -20°C - 70°C (-4°F - 158°F) |
Wavelength range: 0.19 -20µm
Power measurement range: 0.5W-100W
Single channel/ multi-channel power measurement
PC upper computer software display measurement
Part Number | STC-TS100-USB |
Power Range | 0.5 W - 100 W |
Sensitive Diameter | 25 mm |
Continuous Measurement Time (<80 W) | 2 h |
Continuous Measurement Time (80-100 W) | ≤8 min |
Probe Coating Film | Broadband coating |
Probe Material | Thermopile |
Wavelength Range | 0.19-20 μm |
Max. Average Power Density | 45 kW/cm2 |
Sensitivity | 0.1 W |
Calibration Uncertainty (k=2) | ±2% |
Response Time (0-90%) | <7 sec. |
Linearity | ±1% |
Cooling Method | Fan cooling |
Computer Interface | USB 1.1 and USB 2.0 |
Temperature (Operating) | 5°C - 45°C (41°F - 113°F) |
Temperature (Storage) | -20°C - 70°C (-4°F - 158°F) |
Wavelength range: 0.19 -15µm
Power measurement range: 100µW-5W
Single channel/ multi-channel power measurement
PC upper computer software display measurement
Part Number | STC-HS1-USB | STC-HS5-USB |
Probe Model | STC-HS1-USB | STC-HS5-USB |
Power Range | 100µW - 1 W | 500µW - 5 W |
Sensitive Diameter | 8.5 mm | 8.5 mm |
Probe Coating Film | Broadband coating | |
Probe Material | Thermopile | |
Wavelength Range | 0.19-15 μm | |
Max. Average Power Density | 1.5 kW/cm2 | |
Sensitivity | 100µW | 500µW |
Calibration Uncertainty (k=2) | ±2% | |
Response Time (0-90%) | <1 sec. | |
Linearity | ±0.5% | |
Cooling Method | Air cooling | |
Computer Interface | USB 1.1 and USB 2.0 | |
Temperature (Operating) | 5°C - 45°C (41°F - 113°F) | |
Temperature (Storage) | -20°C - 70°C (-4°F - 158°F) |
Wavelength range: 320-1100 nm
High precision: ±2%
Resolution: 2nW
Minimum measuring precision: 0.001nW
Part Number | STC-PS100 |
Detector Model | STC-PD-MN-100 |
Power Range | 2nW -100mW |
Active Area Diameter | 8mm |
Receiving Element | Si Photo diode |
Wavelength Range | 320-1100 nm |
Measurement Display | nW/ µW/ mW/ dBm/ dB |
Calibration Uncertainty (k=2) | ±2% |
Response Time (0-90%) | 0.2sec. |
Total Weight | 0.8kg |
Instrument Power | 100-240 VAC, 50/60 Hz, DC 9V-1.4A |
Temperature (Operating) | 5℃-45℃ (41℉-113℉) |
Temperature (Storage) | -20℃-70℃ (-4℉-158℉) |
Features:
Wavelength range: 0.19 -25µm
Power range: 10mW-2W, 0.5-50W
Active area diameter: 22mm
Model | STC-HP2 | STC-HP50 |
Power Range | 10mW - 2 W | 0.5W - 50 W |
Active Area Diameter | 22 mm | 22 mm |
Wavelength Range | 0.19-25 μm | 0.19-25 μm |
Max. Average Power Density | 15 kW/cm2 | 40 kW/cm2 |
Uncertainty (k=2) | ±2% | ±2% |
Linearity | ±1% | ±1% |
Cooling Method | Air cooling | Air cooling |
Temperature (Operating) | 5°C - 45°C (41°F - 113°F) | 5°C - 45°C (41°F - 113°F) |
Temperature (Storage) | -20°C - 70°C (-4°F - 158°F) | -20°C - 70°C (-4°F - 158°F) |