Automatic multifunctional filter rod tester Weight circumference (roundness) length suction resistance ventilation
The tester is used to measure the weight, circumference (roundness), length, suction resistance, ventilation rate, hardness and other physical parameters of cigarette and filter rod. RT series Cigarette. Filter-Rod multifunction tester adopts modular combined design, with high degree of automation. Each test unit carries out automatic measurement independently and synchronously, and is compatible with samples of various specifications, including conventional cigarettes, medium cigarettes, fine cigarettes, special cigarettes, heated non combustible cigarette rolls, ordinary filter rods, medium filter rods, fine filter rods and special filter rods, It can be combined into comprehensive test bench products of different measurement items according to the actual needs of users.
Performance and characteristics
Optional part
Key technical indexes
Item | Measuring range | Resolution | Precision | |
Weight (0.1mg version) | 0-200,000g | 0.0001g | ±0.0001g | |
Weight (1mg version) | 0-200,000g | 0.001g | ±0.001g | |
Circumference | 15.5-28.5mm | 0.001mm | ±0.002mm | |
Length | 55-150mm | 0.005mm | ±0.01mm | |
Suction resistance | 0~10000 pa(optional0-15000 pa) | 1Pa | ±0.5%FS | |
Ventilation rate | 0-100% | 0.1% | ±1.0%FS | |
|
Pre-pressure | 10g (adjustable) | 0.1g | ±1g |
Pressure | 300g (national standard) | 0.1g | ±1g | |
Time | 15.0s (adjustable) | 0.1s | ±0.1s | |
Displacement | 0-10mm | 0.005mm | ±0.01mm | |
Hardness | 0-100% | 0.1% | ±0.1% |
CFO constant current hole (17.5±0.1 ml/s) made of imported gemstones ensures constant flow,
The measurement accuracy of CFO hole in the pipeline is 17.5 ± 0.1 ml/s;
* Product parameters may change according to the actual situation without prior notice.
Equipment size
L×W×H:0.6×0.6×1.4m(short chassis), 0.6×0.6×1.6m(high chassis),excluding alarm lights and computers.
Comprehensive test bench for short cigarettes (refer to conventional comprehensive test bench for indexes not listed):
Sample length range: 40~150mm
The distance between the measuring point and the end face of the sample is 46-115mm,
The distance between the hardness test point and the end face of the sample is 0〜45mm for the circumference and length unit.
Unit | Measuring range | Resolution | Precision |
Circumference measurement(LS7000) | 15.5-28.5mm | ||
Circumference measurement(IG028) | 15.5-28.5mm | ||
Length Measurement (lg028) | 40-150mm |
Why choose us? Our advantages
Accuracy: The test results are accurate and can provide accurate tobacco composition data.
Reliability: The equipment has high stability and reliable test results, which can meet various testing requirements.
Efficiency: High degree of automation, fast test speed, improve work efficiency.
Comprehensiveness: Can test a variety of tobacco components, including nicotine, nicotine, niacin, etc., to meet different customer needs.
High precision: The use of advanced detection technology, high precision, small error.
1. One of the famous companies in the industry.
2. More than 25 years of experience in product development.
3. With 85000 square meters of production workshop, production capacity is strong.
4. The quality of products has won the praise of domestic and foreign customers.
5. There is no need to reassemble the device after receiving it, and there is a video guide for debugging and use.