Impedance Z
versus
frequency f (typical values)
Pulse handling capability
Maximum permissible voltage change per unit of time for non-sinusoidal voltages
(pulse, sawtooth)
VR | Max. rate of voltage rise Vpp/τ in V/µs (for Vpp = VR) | |||
Lead spacing | ||||
15 mm | 22,5 mm | 27,5 mm | 37,5 mm | |
630 Vdc | 5 000 | 3 000 | 2 000 | — |
1000 Vdc | 9 000 | 5 000 | 3 800 | 2 000 |
1250 Vdc | 12 000 | 7 000 | 4 500 | 2 800 |
1600 Vdc | 16 000 | 11 000 | 6 000 | 3 500 |