Specifications
Brand Name :
Citest
Model Number :
DET-102/114/101,DET-H902
Certification :
CE
Place of Origin :
-
MOQ :
N/A
Price :
negotiation
Supply Ability :
10 M tests/month
Delivery Time :
2-4 Weeks
Packaging Details :
40T/50T
Product :
Fluoxe/tine FLX 500 Ng / Ml Drug Abuse Test Kit , One Step Rapid Diagnostic Test
Cat. No. :
DFLX-102/DFLX-114/DFLX-101
Principle :
Chromatographic Immunoassay
Format :
Dipstick, Cassette, Panel, Cup
Specimen :
Urine
Certificate :
CE
Reading Time :
5 minutes
Pack :
40T/50T
Storage Temperature :
2-30°C
Shelf Life :
2 Years
Sensitivity :
97.0%
Specificity :
96.6%
Accuracy :
96.8%
Cut-Off :
500 ng/mL
Description

Fluox/etine (FLX) 500 ng/ml Drug Abuse Testing Kits Diagnostic Urine Test Kit

Principle Chromatographic Immunoassay
Format Dipstick, Cassette, Panel, Cup
Specimen Urine
Certificate CE
Reading Time 5 minutes
Pack 40T/50T
Storage Temperature 2-30°C
Shelf Life 2 Years
Sensitivity 97.00%
Specificity 96.60%
Accuracy 96.80%
Cut-Off 500 ng/mL

Applications And Description:

Fluo/xetine (FLX), also known by trade names Prozac and Sarafem, among others, is an antidepressant of the selective serotonin reuptake inhibitor (SSRI) class. It is used for the treatment of major depressive disorder, obsessive–compulsive disorder (OCD), bulimia nervosa, panic disorder and premenstrual dysphoric disorder. It may decrease the risk of suicide in those over the age of 65. It has also been used to treat premature ejaculation. Fluox/etine is taken by mouth.

Common side effects include trouble sleeping, sex/ual dysfunction, loss of appetite, dry mouth, rash and abnormal dreams. Serious side effects include serotonin syndrome, mania, seizures, an increased risk of suicidal behavior in people under 25 years old and an increased risk of bleeding.

If stopped suddenly, a withdrawal syndrome may occur with anxiety, dizziness and changes in sensation. It is unclear if it is safe in pregnancy. If already on the medication, it may be reasonable to continue during breastfeeding. Its mechanism of action is not entirely clear but believed to be related to increasing serotonin activity in the brain.


How to use?

Allow test, urine specimen, and/or controls to reach room temperature (15-30°C) prior to testing.
1. Bring the pouch to room temperature before opening it. Remove the test cassette from the sealed pouch and use it within one hour.
2. Place the test device on a clean and level surface. Hold the dropper vertically and transfer 3 full drops of urine (approx. 120μL) to the specimen well (S) of the test cassette, and then start the timer. Avoid trapping air bubbles in the specimen well (S). See the illustration below.
3. Wait for the colored line(s) to appear. Read results at 5 minutes. Do not interpret the result after 10 minutes.

Fluox/etine FLX 500Ng/Ml Drug Abuse Test Kit One Step Rapid Diagnostic Test

【DIRECTIONS FOR PANEL USE】
Allow test, urine specimen, and/or controls to reach room temperature (15-30°C) prior to testing.
1. Bring the pouch to room temperature before opening it. Remove the test panel from the sealed pouch and use it within one hour.
2. Remove the cap.
3. With the arrow pointing toward the urine specimen, immerse the test panel vertically in the urine specimen for at least 10 to 15 seconds. Immerse the strip to at least the level of the wavy lines, but not above the arrow on the test panel.
4. Replace the cap and place the test panel on a non-absorbent flat surface.
5. Start the timer and wait for the colored line(s) to appear.

Fluox/etine FLX 500Ng/Ml Drug Abuse Test Kit One Step Rapid Diagnostic Test


DIRECTIONS FOR DIPSTICK USE
Allow test, urine specimen, and/or controls to reach room temperature (15-30°C) prior to testing.
1. Bring the pouch or closed canister to room temperature before opening it. Remove the Test Dipstick from the sealed pouch and use it within one hour.
2. With arrows pointing toward the urine specimen, immerse the Test Dipstick vertically in the urine specimen for at least 10-15 seconds. Do not pass the maximum line (MAX) on the Test Dipstick when immersing the strip. See the illustration below.
3. Place the test dipstick on a non-absorbent flat surface, start the timer and wait for the colored line(s) to appear. Read results at 5 minutes. Do not interpret the result after 10 minutes.

Fluox/etine FLX 500Ng/Ml Drug Abuse Test Kit One Step Rapid Diagnostic Test

INTERPRETATION OF RESULTS

(Please refer to the illustration above)

NEGATIVE:* Two lines appear. One color line should be in the control region (C), and another apparent color line should be in the test region (T). This negative result indicates that the Fluoxe/tine (FLX) concentration is below the detectable cutoff level.

*NOTE: The shade of color in the test region (T) may vary, but it should be considered negative whenever there is even a faint color line.

POSITIVE: One color line appears in the control region (C). No line appears in the test region (T). This positive result indicates that the Flu/oxetine (FLX) concentration is above the detectable cutoff level.

INVALID: Control line fails to appear. Insufficient specimen volume or incorrect procedural techniques are the most likely reasons for control line failure. Review the procedure and repeat the test with a new test Dipstick. If the problem persists, discontinue using the test Dipstick immediately and contact your local distributor.

Order Information

Cat. No. Product Specimen Pack
DFLX-102 Fluox/etine (FLX) Rapid Test Cassette Urine 40T
DFLX-114 Fluox/etine (FLX) Rapid Test Panel Urine 40 T
DFLX-101 Fluox/etine (FLX) Rapid Test Dipstick Urine 50 T

Send your message to this supplier
Send Now

Fluox/etine FLX 500Ng/Ml Drug Abuse Test Kit One Step Rapid Diagnostic Test

Ask Latest Price
Brand Name :
Citest
Model Number :
DET-102/114/101,DET-H902
Certification :
CE
Place of Origin :
-
MOQ :
N/A
Price :
negotiation
Contact Supplier
Fluox/etine FLX 500Ng/Ml Drug Abuse Test Kit One Step Rapid Diagnostic Test
Fluox/etine FLX 500Ng/Ml Drug Abuse Test Kit One Step Rapid Diagnostic Test
Fluox/etine FLX 500Ng/Ml Drug Abuse Test Kit One Step Rapid Diagnostic Test

CITEST DIAGNOSTICS INC.

Verified Supplier
3 Years
zhejiang, hangzhou
Business Type :
Manufacturer, Exporter, Trading Company
Total Annual :
80000000-100000000
Employee Number :
500~10000
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement